{"id":23090,"date":"2026-09-26T11:46:01","date_gmt":"2026-09-26T11:46:01","guid":{"rendered":"https:\/\/www.examlabs.com\/certification\/?p=23090"},"modified":"2026-09-26T11:46:01","modified_gmt":"2026-09-26T11:46:01","slug":"nadca-ascs-practice-test-questions-and-exam-dumps-part6-q101-120","status":"publish","type":"post","link":"https:\/\/www.examlabs.com\/certification\/nadca-ascs-practice-test-questions-and-exam-dumps-part6-q101-120\/","title":{"rendered":"NADCA ASCS Practice Test Questions and Exam Dumps Part6 Q101-120"},"content":{"rendered":"<p><b>View Full <\/b><a href=\"https:\/\/www.examlabs.com\/ascs-exam-dumps\"><b>NADCA ASCS Exam Dumps<\/b><\/a><b> and Practice Test Dumps.<\/b><\/p>\n<p><b><br \/>\n<\/b><b>Question 101. What should be done with damper positions before duct cleaning<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Remove all dampers<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Fully close every damper<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Mark their original positions<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Replace all damper motors<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 3. Mark their original positions<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Damper positions and other air directional mechanical devices should be marked before cleaning begins. This allows technicians to return the components to their original operating positions after the work is completed. Moving dampers can be necessary to gain access or clean surrounding surfaces, but leaving them in altered positions may change airflow and system balance. NADCA commercial cleaning guidance specifically calls for marking these devices before cleaning and restoring them afterward. This simple step helps ensure that cleaning activity does not unintentionally change the normal operation of the HVAC system.<\/span><\/p>\n<p><b>Question 102. What should happen to dampers after duct cleaning<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Restore them to their marked positions<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Leave them fully open<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Remove them permanently<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Seal them closed<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 1. Restore them to their marked positions<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">After cleaning is complete, dampers and other air directional devices should be returned to the positions recorded before work started. These components control airflow through branches, zones, and other portions of the HVAC system. Leaving them in different positions can change system balance and affect comfort or performance. NADCA specifications therefore require technicians to mark positions before cleaning and restore the devices afterward. Restoration of normal operating conditions is part of completing the project properly rather than treating contaminant removal as the only responsibility of the technician.<\/span><\/p>\n<p><b>Question 103. What should determine whether a coil receives dry or wet cleaning<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Building age only<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Outdoor temperature<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Number of occupants<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Coil and drain pan inspection<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 4. Coil and drain pan inspection<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">NADCA commercial cleaning guidance calls for visual inspection of the coil and drain pan to determine whether dry cleaning or wet cleaning is appropriate. The selected method should reflect the condition of the coil, the type and amount of contamination, accessibility, and the ability to control moisture and debris. Using wet cleaning automatically on every coil is not appropriate because system conditions can vary. Inspection before cleaning allows the technician to select the method most likely to achieve a visibly clean result without damaging the equipment or surrounding components.<\/span><\/p>\n<p><b>Question 104. What should happen to a coil during the cleaning process<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> It should remain connected to every duct section<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> It should be isolated from the duct system<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> It should be removed on every project<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> It should be covered with insulation<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 2. It should be isolated from the duct system<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">A coil should be isolated from the duct system during cleaning so removed particles and cleaning debris do not migrate into other HVAC components. NADCA specifications require contractors to prevent particles removed from the coil from redepositing in unintended areas. Isolation is therefore an important contamination control measure. It allows the technician to focus cleaning on the coil while protecting surrounding ductwork and previously cleaned surfaces. Proper isolation should be combined with appropriate collection, water control when wet methods are used, and cleanliness verification before the system is returned to normal operation.<\/span><\/p>\n<p><b>Question 105. What cleanliness result should coil cleaning achieve<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Visibly clean<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Completely sterile<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Newly coated<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Permanently dry<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 1. Visibly clean<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">NADCA specifications require coil cleaning methods to render the coil visibly clean according to the applicable standard. The purpose is to remove contamination from the coil surfaces rather than merely perform a certain number of cleaning passes. A clean coil can also support better airflow and heat transfer when contamination was restricting performance. After cleaning, the technician should inspect the coil and surrounding components to verify the result. If contamination remains, additional work may be required before the cleaning can be considered complete.<\/span><\/p>\n<p><b>Question 106. Why should removed coil debris be controlled<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> To increase refrigerant pressure<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> To change coil temperature<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> To prevent redeposition elsewhere<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> To increase fan speed<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 3. To prevent redeposition elsewhere<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Debris removed from a coil should not be allowed to migrate into ductwork, air handling equipment, or previously cleaned surfaces. If contamination is simply moved from one component to another, the source removal objective has not been achieved. NADCA specifications require the coil to be isolated during cleaning and direct contractors to prevent removed particles from migrating or redepositing in unintended areas. Effective collection and containment therefore remain important even when the component being cleaned is relatively small compared with the complete HVAC system.<\/span><\/p>\n<p><b>Question 107. What does a plenum commonly provide in an HVAC system<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Refrigerant storage<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Air distribution or collection space<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Electrical generation<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Condensate treatment<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 2. Air distribution or collection space<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">A plenum is an enclosed space used to distribute or collect air within an HVAC system. Supply plenums receive conditioned air and distribute it toward downstream ducts, while return plenums collect air returning from occupied areas. Because significant airflow passes through these spaces, dust and debris can accumulate on their internal surfaces. Plenums should therefore be considered during HVAC assessment and cleaning rather than treating only visible branch ducts. Understanding component function helps an ASCS technician identify appropriate access locations and plan an effective source removal sequence.<\/span><\/p>\n<p><b>Question 108. What is the main function of a supply register<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Collect condensate<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Control refrigerant flow<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Filter return air<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Deliver conditioned air into a space<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 4. Deliver conditioned air into a space<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">A supply register is an air distribution device through which conditioned air enters an occupied space. Registers may include adjustable blades or dampers that influence airflow direction or volume. Because they are part of the air distribution system, registers can collect dust and should be evaluated as part of the overall HVAC cleaning scope. Cleaning visible registers alone does not constitute complete system cleaning when contamination exists elsewhere. NADCA emphasizes considering the HVAC system as an interconnected assembly and using source removal methods where cleaning is required.<\/span><\/p>\n<p><b>Question 109. What is the purpose of a return grille<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Allow room air to enter the return system<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Heat the supply air<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Drain water from a coil<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Increase refrigerant flow<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 1. Allow room air to enter the return system<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">A return grille provides an opening through which air from an occupied space enters the return air system. The air then travels back toward the air handling equipment for filtration, conditioning, mixing, or recirculation. Return grilles can accumulate particulate material because they continually handle air from occupied spaces. They can also provide useful existing access to duct interiors during inspection or cleaning. NADCA recommends using suitable existing openings such as return grilles and supply diffusers when possible before creating additional duct access.<\/span><\/p>\n<p><b>Question 110. What is the main purpose of an exhaust air system<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Deliver heated air<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Increase return airflow<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Remove air from a building or space<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Store conditioned air<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 4. Remove air from a building or space<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">An exhaust air system removes air from a building or specific area and discharges it away from the occupied environment. Exhaust systems are commonly used in spaces where odors, moisture, contaminants, or process air need to be removed. These systems can accumulate debris and may require assessment and cleaning depending on their use and condition. An ASCS technician should understand the difference between supply, return, outdoor, and exhaust airflow because cleaning procedures and contamination characteristics can vary according to the function of each system.<\/span><\/p>\n<p><b>Question 111. What is the purpose of an economizer in an HVAC system<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Capture condensate<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Use suitable outdoor air for cooling<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Increase duct contamination<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Lubricate fan bearings<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 2. Use suitable outdoor air for cooling<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">An economizer allows an HVAC system to use outdoor air for cooling when outdoor conditions are favorable. Dampers and controls regulate outdoor and return air according to system design. Because the outdoor air path can introduce dust, pollen, and other environmental contaminants, economizer components and outdoor air sections should be evaluated during inspection. Technicians should understand the function of dampers and mixing sections so cleaning does not interfere with their movement or control. Mechanical system knowledge is an important part of ASCS competence because cleaning work occurs within operating HVAC equipment.<\/span><\/p>\n<p><b>Question 112. What component moves air through many forced air HVAC systems<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Condensate pan<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Thermostat<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Blower or fan<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Drain trap<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 3. Blower or fan<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">The blower or fan provides the mechanical force that moves air through many HVAC systems. Fan blades, housings, and related surfaces can accumulate particulate material, which may affect airflow and system performance when contamination becomes significant. NADCA includes fans among the nonporous air handling unit components that can require cleaning. The selected cleaning procedure should remove contamination without damaging blades, motors, balance weights, controls, or other components. The technician should also ensure that equipment is safely deenergized before working around moving machinery.<\/span><\/p>\n<p><b>Question 113. What does a heat exchanger primarily transfer<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Heat between separated media<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Electrical current<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Duct pressure only<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Condensate between pans<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 1. Heat between separated media<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">A heat exchanger transfers thermal energy between separate media without requiring them to mix directly. In HVAC equipment, heat exchangers appear in many forms depending on the heating or cooling system design. An ASCS technician should recognize heat exchanger components and avoid cleaning methods that might damage them. Mechanical systems knowledge is included in the ASCS exam because technicians need to understand the function and sensitivity of components encountered during inspection and cleaning. Cleaning specialists should also recognize when equipment conditions require evaluation by a qualified HVAC service professional rather than attempting repairs outside their scope.<\/span><\/p>\n<p><b>Question 114. What is a primary purpose of HVAC insulation<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Increase electrical voltage<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Stop fan rotation<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Change duct dimensions<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Reduce unwanted heat transfer<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 4. Reduce unwanted heat transfer<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">HVAC insulation reduces unwanted heat gain or heat loss and can also help control condensation when correctly designed and installed. Duct insulation can be located externally or as internal fibrous lining. Cleaning methods must account for the type and condition of insulation because aggressive agitation or excessive moisture can damage porous materials. NADCA guidance recognizes restoration and replacement as necessary when components cannot be returned to acceptable condition through cleaning. Technicians should therefore evaluate insulation rather than assuming it can be treated in the same manner as smooth sheet metal.<\/span><\/p>\n<p><b>Question 115. What should be done with compromised air side surfaces<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Document them for restoration or replacement<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Ignore them after cleaning<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Cover them with dust<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Increase fan speed<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 1. Document them for restoration or replacement<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">NADCA states that air side HVAC surfaces found to be compromised during cleanliness evaluation or cleaning should be documented for restoration or replacement as required. Damage can include degraded insulation, corrosion, deterioration, or other conditions that prevent proper cleaning or continued performance. Documentation provides the building owner with a record of conditions that need corrective action. Restoration should occur after mechanical cleaning, and replacement becomes necessary when acceptable cleanliness cannot be achieved through cleaning and restoration.<\/span><\/p>\n<p><b>Question 116. What must happen to components damaged by catastrophic water exposure<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> They must always remain in service<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> They should receive appropriate restoration procedures<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> They should only be painted<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> They should be ignored if airflow continues<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 3. They should receive appropriate restoration procedures<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">NADCA states that HVAC components subjected to catastrophic events such as flood or water damage must be addressed through restoration procedures. Water can introduce contaminants, damage porous materials, cause corrosion, and create conditions supporting microbial growth. Mechanical cleaning alone may not be sufficient when materials have been compromised. The technician should document affected components and determine whether cleaning, restoration, or replacement is needed. If acceptable cleanliness cannot be achieved, replacement is required.<\/span><\/p>\n<p><b>Question 117. What should be corrected when degradation affects HVAC performance<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> The customer invoice<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Building paint<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Outdoor landscaping<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> The compromised component condition<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 4. The compromised component condition<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Component degradation that compromises HVAC performance should be corrected through appropriate restoration procedures when possible. NADCA recognizes restoration as preparation, refurbishment, resurfacing, repair, or replacement of surfaces common to the air stream. Cleaning removes contamination, but it does not automatically repair damaged materials or restore structural condition. The contractor should document degradation found during assessment or cleaning and determine the appropriate corrective approach. Leaving a degraded component untreated can reduce the durability of the cleaning result and may continue to affect system operation.<\/span><\/p>\n<p><b>Question 118. What should determine whether portable or truck mounted vacuum equipment is used<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Contractor preference only<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Project and system requirements<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Building wall color<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Outdoor temperature only<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 2. Project and system requirements<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">NADCA explains that both portable and truck mounted vacuum systems can perform HVAC cleaning correctly when they are properly selected and used. Truck mounted equipment is often more powerful, while portable equipment can be positioned closer to indoor ductwork. Selection should therefore consider duct size, hose length, access, available power, required airflow, filtration, exhaust location, and the ability to maintain negative pressure. The correct equipment is the system that meets the needs of the particular project rather than whichever type the contractor generally prefers.<\/span><\/p>\n<p><b>Question 119. What is the first major step before developing an HVAC cleaning scope<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Assess the system condition<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Apply antimicrobial treatment<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Replace every filter<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Begin duct cutting<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 3. Assess the system condition<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">A cleaning scope should be based on an assessment of the actual HVAC system. Assessment helps identify contamination, damaged materials, moisture conditions, system configuration, safety hazards, access needs, and components requiring cleaning or restoration. NADCA&#8217;s current ACR Standard is structured around assessment, cleaning, restoration, and verification rather than beginning immediately with mechanical cleaning. A system specific assessment allows the contractor to choose appropriate equipment, engineering controls, containment, cleaning methods, scheduling, and verification procedures.<\/span><\/p>\n<p><b>Question 120. What is the main goal of cleanliness verification<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Increase project duration<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Confirm the system achieved the required cleanliness<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Replace the initial inspection<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Eliminate documentation<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 2. Confirm the system achieved the required cleanliness<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Cleanliness verification determines whether cleaning procedures produced the required result. NADCA&#8217;s current ACR Standard includes formal verification methods such as the Surface Comparison Test and NADCA Vacuum Test. Verification provides a basis for deciding whether a component is acceptable or requires additional cleaning. This separates professional HVAC cleaning from work judged only by time spent or equipment used. The project objective is to achieve a defined level of cleanliness while maintaining system integrity and protecting workers and occupants. Verification confirms that this objective has actually been met.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>View Full NADCA ASCS Exam Dumps and Practice Test Dumps. Question 101. What should be done with damper positions before duct cleaning Remove all dampers Fully close every damper Mark their original positions Replace all damper motors Correct Answer: 3. Mark their original positions Explanation: Damper positions and other air directional mechanical devices should be [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[1648,1647],"tags":[],"_links":{"self":[{"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/posts\/23090"}],"collection":[{"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/comments?post=23090"}],"version-history":[{"count":1,"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/posts\/23090\/revisions"}],"predecessor-version":[{"id":23091,"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/posts\/23090\/revisions\/23091"}],"wp:attachment":[{"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/media?parent=23090"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/categories?post=23090"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/tags?post=23090"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}