{"id":23100,"date":"2026-09-26T11:47:14","date_gmt":"2026-09-26T11:47:14","guid":{"rendered":"https:\/\/www.examlabs.com\/certification\/?p=23100"},"modified":"2026-09-26T11:47:14","modified_gmt":"2026-09-26T11:47:14","slug":"nadca-ascs-practice-test-questions-and-exam-dumps-part11-q201-220","status":"publish","type":"post","link":"https:\/\/www.examlabs.com\/certification\/nadca-ascs-practice-test-questions-and-exam-dumps-part11-q201-220\/","title":{"rendered":"NADCA ASCS Practice Test Questions and Exam Dumps Part11 Q201-220"},"content":{"rendered":"<p><b>View Full <\/b><a href=\"https:\/\/www.examlabs.com\/ascs-exam-dumps\"><b>NADCA ASCS Exam Dumps<\/b><\/a><b> and Practice Test Dumps.<\/b><\/p>\n<p><b><br \/>\n<\/b><b>Question 201. What is an ASCS qualified to serve as on HVAC cleaning projects<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Building architect<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Project manager<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Refrigerant manufacturer<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Electrical inspector<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 2. Project manager<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">NADCA describes an Air Systems Cleaning Specialist as a professional qualified to serve as a project manager for residential and commercial HVAC cleaning and restoration projects. This responsibility requires more than operating cleaning equipment. An ASCS must understand assessment, mechanical systems, cleaning procedures, safety, restoration, standards, and project coordination. The project manager role includes helping ensure that work is planned and performed according to recognized industry practices. The technician must also recognize project conditions that require another qualified professional rather than working outside the limits of the ASCS role.<\/span><\/p>\n<p><b>Question 202. What should be done when a contractor cannot meet an applicable cleaning standard<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Hide the limitation<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Continue without changes<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Remove the project specification<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Inform the client of the obstacle<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 4. Inform the client of the obstacle<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Professional HVAC cleaning requires clear communication when conditions prevent work from meeting applicable standards or project requirements. NADCA states that technicians should follow industry standards and guidelines and inform the client about obstacles that may prevent compliance. Examples can include inaccessible components, damaged materials, unsafe conditions, or building restrictions. The issue should be documented and addressed before work proceeds in a manner that could produce an incomplete or unsafe result. Transparent communication helps the customer understand project limitations and supports development of an appropriate corrective plan.<\/span><\/p>\n<p><b>Question 203. What is the primary purpose of cross contamination control<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Prevent contaminants from reaching occupied areas<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Increase system pressure<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Reduce coil temperature<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Increase duct dimensions<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 1. Prevent contaminants from reaching occupied areas<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Cross contamination controls are intended to prevent contaminants disturbed during cleaning from moving into occupied areas or other unaffected portions of the building. NADCA requires engineering controls to control contaminant discharge during HVAC cleaning. These controls can include negative pressure, containment, collection equipment, protective coverings, and appropriate work practices. Cleaning should remove contamination from the HVAC system rather than redistribute it. Effective cross contamination control protects workers, occupants, furnishings, and previously cleaned areas while source removal procedures are being performed.<\/span><\/p>\n<p><b>Question 204. What instrument can validate negative pressure in containment<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Hygrometer<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Thermometer<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Manometer<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Tachometer<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 3. Manometer<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">A manometer can be used to verify that a containment area is being maintained under negative pressure. NADCA requires negative pressure to be sufficient to prevent airborne particulate material from migrating out of the contained work area. Simply operating an air filtration device is not enough because the technician needs evidence that the intended pressure relationship exists. Airflow measuring or monitoring equipment can also be used where appropriate. Verification should continue as needed throughout the project because changing openings, equipment performance, or building conditions can affect pressure relationships.<\/span><\/p>\n<p><b>Question 205. Why should return air grilles be sealed during some containment projects<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Prevent contaminants from entering the HVAC system<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Increase heating capacity<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Improve refrigerant flow<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Increase fan speed<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 1. Prevent contaminants from entering the HVAC system<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">During containment work, return air openings may need to be sealed so airborne contamination generated in the work area is not pulled into the HVAC system and redistributed elsewhere in the building. NADCA training materials identify sealing return air grilles as one element of effective negative pressure containment. The exact controls depend on the project conditions and system configuration. The objective is to control contaminant movement while cleaning is performed. Containment should work together with negative pressure and appropriate filtration rather than relying on a single control method.<\/span><\/p>\n<p><b>Question 206. What should be done before dismantling a containment enclosure<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Increase supply airflow<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Remove the HEPA filters<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Turn on the HVAC system<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Clean the interior containment surfaces<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 4. Clean the interior containment surfaces<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Before a containment enclosure is moved or dismantled, NADCA requires its interior surfaces to be cleaned using methods such as wet wiping or HEPA vacuuming. Contamination can settle on the containment material during cleaning operations. Dismantling dirty barriers without first cleaning them could release that material into surrounding spaces. In healthcare environments, additional post remediation verification may also be required before containment is removed. Proper dismantling is therefore part of contamination control and should be planned as carefully as the initial construction of the enclosure.<\/span><\/p>\n<p><b>Question 207. What should determine the gauge of a prefabricated duct access door<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Building occupancy<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Duct pressure class<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Outdoor humidity<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Filter efficiency<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 2. Duct pressure class<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">NADCA states that the gauge of a prefabricated duct access door should be based on the pressure class of the duct system and installed according to the manufacturer&#8217;s specifications. Access doors become part of the duct system and must therefore withstand the operating conditions of that system. An unsuitable door can leak, deform, or compromise duct integrity. Proper access design considers structural strength, airflow, sealing, and future service access. Technicians should not select access doors simply because they are convenient or readily available.<\/span><\/p>\n<p><b>Question 208. What rating limits apply to materials exposed to the internal airstream at access openings<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> No ratings are required<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Only water resistance matters<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Flame spread and smoke development limits<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Refrigerant pressure limits<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 3. Flame spread and smoke development limits<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Materials used for duct access doors or permanent panels that are exposed to the internal airstream must meet applicable fire performance requirements. NADCA specifies limits for flame spread and smoke development based on recognized testing requirements. These provisions help ensure that creating a service opening does not introduce an inappropriate combustible material into the HVAC system. Access work must preserve system safety as well as structural and functional integrity. Applicable UL, SMACNA, NFPA, and local code requirements should also be considered when selecting and installing access materials.<\/span><\/p>\n<p><b>Question 209. What should be in place before an air handling unit wash down begins<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> A working drainage system<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Maximum fan speed<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Open electrical panels<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Removed condensate drains<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 4. A working drainage system<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">NADCA&#8217;s commercial cleaning guidance calls for an operative drainage system to be in place before wash down procedures begin. Wet cleaning can generate significant water and debris that must be captured and removed without flooding the equipment or surrounding areas. A blocked or missing drain can create standing water, moisture damage, and additional contamination concerns. Drainage planning should therefore occur before water is introduced. Technicians should also protect sensitive electrical and porous components and manage wastewater according to applicable requirements.<\/span><\/p>\n<p><b>Question 210. Which air handling components should be included in cleaning when contaminated<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Only filters<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Internal surfaces components and condensate collectors<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Only exterior panels<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Only thermostats<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 1. Internal surfaces components and condensate collectors<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">NADCA&#8217;s commercial cleaning guidance calls for cleaning air handling unit internal surfaces, components, condensate collectors, and drains as required by the project scope and system condition. Limiting work to easily visible exterior surfaces would leave contamination inside the active air path. Coils, fans, drain pans, internal insulation, and related components can all influence system hygiene. A professional assessment should determine which components require cleaning, and the selected methods should preserve the equipment while removing visible contamination.<\/span><\/p>\n<p><b>Question 211. What should happen when an inaccessible duct area requires cleaning<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Ignore the area<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Clean only the nearest register<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Create an appropriate service opening<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Increase fan speed<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 3. Create an appropriate service opening<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">When contamination exists in an area that cannot be effectively reached through existing openings, an appropriate service opening may need to be created. NADCA specifically calls for access openings where necessary to accommodate cleaning of otherwise inaccessible areas. The opening must be designed so the system retains its structural, thermal, and functional integrity and normal airflow is not affected. After cleaning and verification, the opening should be closed with suitable materials and methods. Access creation is therefore part of proper cleaning when existing openings are insufficient.<\/span><\/p>\n<p><b>Question 212. What should happen to visible contamination inside duct systems<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> It should be covered with insulation<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> It should be mechanically removed<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> It should be painted over<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> It should be moved downstream<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 2. It should be mechanically removed<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">NADCA&#8217;s commercial cleaning checklist calls for duct systems to be mechanically cleaned to remove visible contaminants. Mechanical source removal can include brushes, compressed air tools, contact vacuuming, and other methods appropriate for the duct material. Negative pressure collection equipment captures loosened debris so it does not escape into the building. The objective is actual removal rather than relocation or concealment. Cleaning methods should be selected according to material type and condition so contamination is removed without damaging the HVAC system.<\/span><\/p>\n<p><b>Question 213. What is the best reason to inspect a VAV box during system cleaning<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> It contains air stream components that can collect contamination<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> It stores refrigerant<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> It controls building plumbing<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> It powers the electrical service<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 1. It contains air stream components that can collect contamination<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">A variable air volume box is part of the air distribution system and can include internal dampers, controls, reheat coils, insulation, or fan powered components. Dust and debris can accumulate on these surfaces just as they can inside ductwork. NADCA commercial guidance identifies VAV boxes among the components considered during HVAC cleaning projects. An ASCS technician should recognize these devices and inspect them as appropriate to the project scope. Cleaning methods must protect controls and other delicate internal components while removing relevant contamination.<\/span><\/p>\n<p><b>Question 214. Why should registers and diffusers be included in a complete cleaning scope<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> They control refrigerant<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> They replace air filters<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> They remove condensate<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> They are part of the air distribution path<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 4. They are part of the air distribution path<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Registers, grilles, and diffusers are part of the HVAC air distribution system and can accumulate dust and debris on surfaces exposed to airflow. NADCA commercial cleaning guidance identifies air distribution devices as components that should be considered within the project scope. Cleaning only these visible devices does not constitute complete duct cleaning, but leaving heavily contaminated devices untouched can allow debris to remain at the final point of air delivery or return. Components should be cleaned using methods appropriate for their construction and finish.<\/span><\/p>\n<p><b>Question 215. What is the best reason to include exhaust fans in system assessment<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> They can accumulate contamination and affect airflow<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> They control refrigerant charge<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> They replace fire dampers<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> They measure humidity<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 2. They can accumulate contamination and affect airflow<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Exhaust fans move air out of a building or specific space and can collect grease, dust, lint, or other contaminants depending on their application. Accumulated material can affect fan performance and system cleanliness. NADCA&#8217;s commercial cleaning guidance includes exhaust fans among components considered during HVAC cleaning work. Technicians should inspect fan blades, housings, and accessible air side surfaces while following lockout and other safety procedures. Cleaning should restore cleanliness without damaging balance weights, motors, controls, or associated components.<\/span><\/p>\n<p><b>Question 216. What should a contractor provide to show that cleaning was completed correctly<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> New ductwork on every project<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> A larger vacuum<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Verification through inspection or testing<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> A new thermostat<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 3. Verification through inspection or testing<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">NADCA&#8217;s commercial checklist includes verification of cleanliness through inspection or testing according to applicable NADCA requirements. Professional cleaning is judged by the achieved result rather than by the amount of time spent or the type of equipment used. Visual inspection and recognized testing methods can help determine whether the required level of cleanliness has been reached. Verification also provides the client with evidence that the defined scope was completed properly. If the required cleanliness is not achieved, additional cleaning should be performed before the work is considered complete.<\/span><\/p>\n<p><b>Question 217. What should a post project report primarily document<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Completed work and relevant project results<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Employee vacation schedules<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Building tax records<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Refrigerant sales history<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 4. Completed work and relevant project results<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">A post project report provides a record of the work performed and relevant project results. Depending on the project, documentation can include cleaned components, observed conditions, verification results, photographs, access openings, restoration work, and unresolved issues requiring additional action. NADCA&#8217;s commercial checklist specifically identifies the post project report as part of a professional HVAC cleaning project. Good documentation helps the customer understand what was completed and creates a useful record for future inspections, maintenance, and cleaning decisions.<\/span><\/p>\n<p><b>Question 218. Why should odors be controlled during HVAC cleaning<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> To increase duct pressure<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> To protect occupants and prevent unnecessary exposure<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> To increase coil temperature<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> To reduce duct size<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 2. To protect occupants and prevent unnecessary exposure<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Cleaning products, disturbed contamination, coatings, or other project activities can create odors or emissions that affect occupants. NADCA&#8217;s commercial cleaning guidance includes controlling odors as part of general HVAC system cleaning requirements. Contractors should select suitable products, provide ventilation when required, and schedule activities to reduce unnecessary exposure. Safety Data Sheets and manufacturer instructions should be reviewed when chemical products are used. Odor control is part of protecting the occupied environment and should be considered during project planning rather than only after complaints occur.<\/span><\/p>\n<p><b>Question 219. What should a technician do if cleaning could damage a fragile HVAC material<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> Select a less damaging suitable method<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Use the most aggressive brush available<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Ignore the material condition<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> Increase compressed air pressure without limit<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 3. Select a less damaging suitable method<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Cleaning methods should remove contamination without damaging the HVAC system. Fragile materials such as certain insulation, duct liner, flexible duct, coatings, or aged components may not tolerate aggressive mechanical agitation. The technician should evaluate the material condition and select a method appropriate for that surface. If acceptable cleanliness cannot be achieved without causing damage, restoration or replacement may be required. NADCA emphasizes preserving system integrity throughout assessment, cleaning, and restoration rather than treating contaminant removal as the only project objective.<\/span><\/p>\n<p><b>Question 220. What is the main reason ACR uses a consistent procedural framework<\/b><\/p>\n<ol>\n<li><b><\/b><span style=\"font-weight: 400;\"> To make every HVAC system identical<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> To eliminate professional judgment<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> To replace all building codes<\/span><\/li>\n<li><b><\/b><span style=\"font-weight: 400;\"> To establish consistent expectations for quality and safety<\/span><\/li>\n<\/ol>\n<p><b>Correct Answer: 1. To establish consistent expectations for quality and safety<\/b><\/p>\n<p><b>Explanation:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">ACR, The NADCA Standard, provides a recognized framework for assessing, cleaning, restoring, and verifying HVAC systems. The current 2025 edition includes engineering controls, containment, inspections, scope development, equipment use, cleaning methods, and cleanliness verification. A consistent framework helps contractors, facility managers, specifiers, and customers understand what professional work should involve. It does not make every project identical because system conditions still require professional judgment. Instead, it establishes common expectations for safe procedures, effective contaminant removal, system protection, and verification of the completed work.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>View Full NADCA ASCS Exam Dumps and Practice Test Dumps. Question 201. What is an ASCS qualified to serve as on HVAC cleaning projects Building architect Project manager Refrigerant manufacturer Electrical inspector Correct Answer: 2. Project manager Explanation: NADCA describes an Air Systems Cleaning Specialist as a professional qualified to serve as a project manager [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[1648,1647],"tags":[],"_links":{"self":[{"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/posts\/23100"}],"collection":[{"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/comments?post=23100"}],"version-history":[{"count":1,"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/posts\/23100\/revisions"}],"predecessor-version":[{"id":23101,"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/posts\/23100\/revisions\/23101"}],"wp:attachment":[{"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/media?parent=23100"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/categories?post=23100"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.examlabs.com\/certification\/wp-json\/wp\/v2\/tags?post=23100"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}