Question 110

An infrastructure specialist needs a focused first investigation before acting. A new three-host vSAN cluster has consistent disks but its hosts cannot communicate over the intended vSAN traffic network. Which investigation best distinguishes the suspected cause in this case?

  1. Compare logical versus physical usage, workload compressibility and feature support for the installed architecture.
  2. Check the vSAN compatibility guide for ESA-certified devices, firmware, network and host platform.
  3. Inspect encryption health, key-provider trust, key backups and documented disaster-recovery access.
  4. Test vSAN VMkernel reachability, VLANs, MTU, routing requirements and cluster membership alerts.

Explanation

Correct Answer

D:

Test vSAN VMkernel reachability, VLANs, MTU, routing requirements and cluster membership alerts. This inspection directly tests the suspected cause. The suitable response is: Configure the supported vSAN VMkernel networking and correct IP reachability before completing cluster storage setup. Expected resolution evidence: All intended hosts join the vSAN cluster, exchange health information and form a usable datastore.

Incorrect Answers

A:

Compare logical versus physical usage, workload compressibility and feature support for the installed architecture. That check targets deduplication and compression feasibility and could be useful in a different incident. The first evidence needed here relates to vsan cluster formation. First examine: Test vSAN VMkernel reachability, VLANs, MTU, routing requirements and cluster membership alerts.

B:

Check the vSAN compatibility guide for ESA-certified devices, firmware, network and host platform. That check targets vsan esa versus osa compatibility and could be useful in a different incident. The first evidence needed here relates to vsan cluster formation. First examine: Test vSAN VMkernel reachability, VLANs, MTU, routing requirements and cluster membership alerts.

C:

Inspect encryption health, key-provider trust, key backups and documented disaster-recovery access. That check targets vsan encryption at rest and could be useful in a different incident. The first evidence needed here relates to vsan cluster formation. First examine: Test vSAN VMkernel reachability, VLANs, MTU, routing requirements and cluster membership alerts.

Question 111

A VVF 9.0 administrator must choose the most appropriate implementation or remediation decision. A business application VM on vSAN must remain available after a single eligible host failure and the cluster has sufficient resources. Which action directly addresses the specific condition?

  1. Investigate the missing eligible resources or topology and remediate before expecting the new policy to become compliant.
  2. Monitor object resynchronization and health until intended policy compliance is restored before scheduling another disruptive action.
  3. Use a supported NFS datastore with correct network reachability and export permissions for the ESX hosts.
  4. Apply a compatible vSAN storage policy providing the required one-failure tolerance, then verify placement compliance.

Explanation

Correct Answer

D:

Apply a compatible vSAN storage policy providing the required one-failure tolerance, then verify placement compliance. Why it works: Storage policy rules govern how vSAN places object components and witnesses to meet a configured fault tolerance target. Acceptance evidence: The VM object is policy-compliant and a supported failure simulation preserves access within the documented tolerance.

Incorrect Answers

A:

Investigate the missing eligible resources or topology and remediate before expecting the new policy to become compliant. It is an action for datastore policy change remediation. The stated case instead requires checking storage policy host failure tolerance before accepting a fix: Review object policy compliance, fault domains, component placement and current resynchronization state.

B:

Monitor object resynchronization and health until intended policy compliance is restored before scheduling another disruptive action. It is an action for resynchronization after host return. The stated case instead requires checking storage policy host failure tolerance before accepting a fix: Review object policy compliance, fault domains, component placement and current resynchronization state.

C:

Use a supported NFS datastore with correct network reachability and export permissions for the ESX hosts. It is an action for vmfs and nfs selection. The stated case instead requires checking storage policy host failure tolerance before accepting a fix: Review object policy compliance, fault domains, component placement and current resynchronization state.

Question 112

A VVF 9.0 administrator is validating whether a targeted correction achieved its purpose. A business application VM on vSAN must remain available after a single eligible host failure and the cluster has sufficient resources. Which observation is the strongest acceptance evidence for this case?

  1. After resource or topology correction, object placement converges and the datastore reports the requested policy as compliant.
  2. The VM object is policy-compliant and a supported failure simulation preserves access within the documented tolerance.
  3. The vSAN encryption configuration reports healthy keys and encrypted storage while planned key-recovery tests succeed.
  4. Resynchronization activity completes and affected objects return to their required storage-policy compliance state.

Explanation

Correct Answer

B:

The VM object is policy-compliant and a supported failure simulation preserves access within the documented tolerance. This evidence verifies the intended remedy, rather than a nearby symptom. Underlying principle: Storage policy rules govern how vSAN places object components and witnesses to meet a configured fault tolerance target. First check: Review object policy compliance, fault domains, component placement and current resynchronization state.

Incorrect Answers

A:

After resource or topology correction, object placement converges and the datastore reports the requested policy as compliant. That observation validates datastore policy change remediation. For Storage policy host failure tolerance, the directly relevant verification is: The VM object is policy-compliant and a supported failure simulation preserves access within the documented tolerance.

C:

The vSAN encryption configuration reports healthy keys and encrypted storage while planned key-recovery tests succeed. That observation validates vsan encryption at rest. For Storage policy host failure tolerance, the directly relevant verification is: The VM object is policy-compliant and a supported failure simulation preserves access within the documented tolerance.

D:

Resynchronization activity completes and affected objects return to their required storage-policy compliance state. That observation validates resynchronization after host return. For Storage policy host failure tolerance, the directly relevant verification is: The VM object is policy-compliant and a supported failure simulation preserves access within the documented tolerance.

Question 113

A reviewer is examining the technical reason for the proposed VVF approach. A business application VM on vSAN must remain available after a single eligible host failure and the cluster has sufficient resources. Which mechanism best explains why the relevant approach works?

  1. vSAN rebuilds or resynchronizes object components as resource availability changes after a failure or maintenance window.
  2. Storage policy rules govern how vSAN places object components and witnesses to meet a configured fault tolerance target.
  3. Compression and related supported data-reduction techniques reduce physical consumption when data patterns are favorable.
  4. vSAN policy enforcement depends on enough eligible object-placement resources across applicable failure domains.

Explanation

Correct Answer

B:

Storage policy rules govern how vSAN places object components and witnesses to meet a configured fault tolerance target. This is the causal mechanism for the case. If the dependency is ignored: An insufficient failure-tolerance policy can leave objects unavailable during the expected fault. A practical validation is: The VM object is policy-compliant and a supported failure simulation preserves access within the documented tolerance.

Incorrect Answers

A:

vSAN rebuilds or resynchronizes object components as resource availability changes after a failure or maintenance window. This describes the technology behind resynchronization after host return, but not why the behavior in the stated case occurs. The relevant dependency is storage policy host failure tolerance, and its inputs must be examined before applying the other mechanism.

C:

Compression and related supported data-reduction techniques reduce physical consumption when data patterns are favorable. This describes the technology behind deduplication and compression feasibility, but not why the behavior in the stated case occurs. The relevant dependency is storage policy host failure tolerance, and its inputs must be examined before applying the other mechanism.

D:

vSAN policy enforcement depends on enough eligible object-placement resources across applicable failure domains. This describes the technology behind datastore policy change remediation, but not why the behavior in the stated case occurs. The relevant dependency is storage policy host failure tolerance, and its inputs must be examined before applying the other mechanism.

Question 114

A change advisory board is assessing the consequence of leaving the stated issue unaddressed. A business application VM on vSAN must remain available after a single eligible host failure and the cluster has sufficient resources. Which risk follows most directly from the described condition?

  1. An insufficient failure-tolerance policy can leave objects unavailable during the expected fault.
  2. Loss of required encryption keys or key-service access can make otherwise healthy stored data unreadable.
  3. Starting additional host maintenance before resynchronization completes can exceed the available failure tolerance.
  4. Repeatedly reapplying an infeasible policy does not create the hosts or fault-domain placement it requires.

Explanation

Correct Answer

A:

An insufficient failure-tolerance policy can leave objects unavailable during the expected fault. This risk directly follows from the observed situation. The mitigating action is: Apply a compatible vSAN storage policy providing the required one-failure tolerance, then verify placement compliance. A focused check is: Review object policy compliance, fault domains, component placement and current resynchronization state.

Incorrect Answers

B:

Loss of required encryption keys or key-service access can make otherwise healthy stored data unreadable. This is a real concern for vsan encryption at rest, but it is not the most direct consequence of the specific condition. In this case, evaluate storage policy host failure tolerance and the effect on the affected workload or management path.

C:

Starting additional host maintenance before resynchronization completes can exceed the available failure tolerance. This is a real concern for resynchronization after host return, but it is not the most direct consequence of the specific condition. In this case, evaluate storage policy host failure tolerance and the effect on the affected workload or management path.

D:

Repeatedly reapplying an infeasible policy does not create the hosts or fault-domain placement it requires. This is a real concern for datastore policy change remediation, but it is not the most direct consequence of the specific condition. In this case, evaluate storage policy host failure tolerance and the effect on the affected workload or management path.

Question 115

An infrastructure specialist needs a focused first investigation before acting. A business application VM on vSAN must remain available after a single eligible host failure and the cluster has sufficient resources. Which investigation best distinguishes the suspected cause in this case?

  1. Inspect encryption health, key-provider trust, key backups and documented disaster-recovery access.
  2. Check vSAN health, resync bytes remaining, object compliance and fault-domain availability.
  3. Review object policy compliance, fault domains, component placement and current resynchronization state.
  4. Inspect storage protocol, export permissions, VMkernel networking and supported NFS version.

Explanation

Correct Answer

C:

Review object policy compliance, fault domains, component placement and current resynchronization state. This inspection directly tests the suspected cause. The suitable response is: Apply a compatible vSAN storage policy providing the required one-failure tolerance, then verify placement compliance. Expected resolution evidence: The VM object is policy-compliant and a supported failure simulation preserves access within the documented tolerance.

Incorrect Answers

A:

Inspect encryption health, key-provider trust, key backups and documented disaster-recovery access. That check targets vsan encryption at rest and could be useful in a different incident. The first evidence needed here relates to storage policy host failure tolerance. First examine: Review object policy compliance, fault domains, component placement and current resynchronization state.

B:

Check vSAN health, resync bytes remaining, object compliance and fault-domain availability. That check targets resynchronization after host return and could be useful in a different incident. The first evidence needed here relates to storage policy host failure tolerance. First examine: Review object policy compliance, fault domains, component placement and current resynchronization state.

D:

Inspect storage protocol, export permissions, VMkernel networking and supported NFS version. That check targets vmfs and nfs selection and could be useful in a different incident. The first evidence needed here relates to storage policy host failure tolerance. First examine: Review object policy compliance, fault domains, component placement and current resynchronization state.

Question 116

A VVF 9.0 administrator must choose the most appropriate implementation or remediation decision. A vSAN administrator wants to improve usable storage efficiency for a protected workload while meeting the selected fault-tolerance objective. Which action directly addresses the specific condition?

  1. Evaluate current vSAN ESA hardware and version compatibility before selecting ESA rather than assuming every OSA design qualifies.
  2. Compare supported erasure-coding and mirroring policy choices against resilience, capacity and cluster topology requirements.
  3. Evaluate space-efficiency capabilities for the selected vSAN architecture and validate measured savings on representative data.
  4. Configure supported vSAN data-at-rest encryption with an approved key provider and operational key-backup procedure.

Explanation

Correct Answer

B:

Compare supported erasure-coding and mirroring policy choices against resilience, capacity and cluster topology requirements. Why it works: Erasure coding can reduce redundancy overhead versus mirroring but has its own layout and minimum-resource requirements. Acceptance evidence: The final policy stays compliant and meets the capacity and performance targets after placement and health verification.

Incorrect Answers

A:

Evaluate current vSAN ESA hardware and version compatibility before selecting ESA rather than assuming every OSA design qualifies. It is an action for vsan esa versus osa compatibility. The stated case instead requires checking mirroring versus erasure coding before accepting a fix: Inspect policy fault-tolerance method, required resources, current topology and the proposed object footprint.

C:

Evaluate space-efficiency capabilities for the selected vSAN architecture and validate measured savings on representative data. It is an action for deduplication and compression feasibility. The stated case instead requires checking mirroring versus erasure coding before accepting a fix: Inspect policy fault-tolerance method, required resources, current topology and the proposed object footprint.

D:

Configure supported vSAN data-at-rest encryption with an approved key provider and operational key-backup procedure. It is an action for vsan encryption at rest. The stated case instead requires checking mirroring versus erasure coding before accepting a fix: Inspect policy fault-tolerance method, required resources, current topology and the proposed object footprint.

Question 117

A VVF 9.0 administrator is validating whether a targeted correction achieved its purpose. A vSAN administrator wants to improve usable storage efficiency for a protected workload while meeting the selected fault-tolerance objective. Which observation is the strongest acceptance evidence for this case?

  1. The selected architecture passes the appropriate compatibility checks and the cluster reports healthy storage components.
  2. Hosts mount the intended NFS share and run test VMs with acceptable latency and documented access control.
  3. Both hosts identify the same datastore with consistent identifiers and the planned migration prerequisite passes.
  4. The final policy stays compliant and meets the capacity and performance targets after placement and health verification.

Explanation

Correct Answer

D:

The final policy stays compliant and meets the capacity and performance targets after placement and health verification. This evidence verifies the intended remedy, rather than a nearby symptom. Underlying principle: Erasure coding can reduce redundancy overhead versus mirroring but has its own layout and minimum-resource requirements. First check: Inspect policy fault-tolerance method, required resources, current topology and the proposed object footprint.

Incorrect Answers

A:

The selected architecture passes the appropriate compatibility checks and the cluster reports healthy storage components. That observation validates vsan esa versus osa compatibility. For Mirroring versus erasure coding, the directly relevant verification is: The final policy stays compliant and meets the capacity and performance targets after placement and health verification.

B:

Hosts mount the intended NFS share and run test VMs with acceptable latency and documented access control. That observation validates vmfs and nfs selection. For Mirroring versus erasure coding, the directly relevant verification is: The final policy stays compliant and meets the capacity and performance targets after placement and health verification.

C:

Both hosts identify the same datastore with consistent identifiers and the planned migration prerequisite passes. That observation validates shared datastore visibility. For Mirroring versus erasure coding, the directly relevant verification is: The final policy stays compliant and meets the capacity and performance targets after placement and health verification.

Question 118

A reviewer is examining the technical reason for the proposed VVF approach. A vSAN administrator wants to improve usable storage efficiency for a protected workload while meeting the selected fault-tolerance objective. Which mechanism best explains why the relevant approach works?

  1. vSAN Express Storage Architecture uses a different data path and hardware requirements than Original Storage Architecture.
  2. Shared block or file datastores expose a common VM storage namespace when host access and protocol configuration agree.
  3. Erasure coding can reduce redundancy overhead versus mirroring but has its own layout and minimum-resource requirements.
  4. vSAN distributes storage objects across networked cluster hosts and relies on consistent host-to-host storage connectivity.

Explanation

Correct Answer

C:

Erasure coding can reduce redundancy overhead versus mirroring but has its own layout and minimum-resource requirements. This is the causal mechanism for the case. If the dependency is ignored: Choosing a capacity-efficient layout without eligible host count or failure domains can make the policy noncompliant. A practical validation is: The final policy stays compliant and meets the capacity and performance targets after placement and health verification.

Incorrect Answers

A:

vSAN Express Storage Architecture uses a different data path and hardware requirements than Original Storage Architecture. This describes the technology behind vsan esa versus osa compatibility, but not why the behavior in the stated case occurs. The relevant dependency is mirroring versus erasure coding, and its inputs must be examined before applying the other mechanism.

B:

Shared block or file datastores expose a common VM storage namespace when host access and protocol configuration agree. This describes the technology behind shared datastore visibility, but not why the behavior in the stated case occurs. The relevant dependency is mirroring versus erasure coding, and its inputs must be examined before applying the other mechanism.

D:

vSAN distributes storage objects across networked cluster hosts and relies on consistent host-to-host storage connectivity. This describes the technology behind vsan cluster formation, but not why the behavior in the stated case occurs. The relevant dependency is mirroring versus erasure coding, and its inputs must be examined before applying the other mechanism.

Question 119

A change advisory board is assessing the consequence of leaving the stated issue unaddressed. A vSAN administrator wants to improve usable storage efficiency for a protected workload while meeting the selected fault-tolerance objective. Which risk follows most directly from the described condition?

  1. Choosing a capacity-efficient layout without eligible host count or failure domains can make the policy noncompliant.
  2. Selecting ESA on unsupported disks, controllers or platform combinations can prevent a valid deployment.
  3. A broken vSAN traffic path can partition storage membership and threaten VM object availability.
  4. Exhausting the free-space buffer can block writes or slow recovery operations during an incident.

Explanation

Correct Answer

A:

Choosing a capacity-efficient layout without eligible host count or failure domains can make the policy noncompliant. This risk directly follows from the observed situation. The mitigating action is: Compare supported erasure-coding and mirroring policy choices against resilience, capacity and cluster topology requirements. A focused check is: Inspect policy fault-tolerance method, required resources, current topology and the proposed object footprint.

Incorrect Answers

B:

Selecting ESA on unsupported disks, controllers or platform combinations can prevent a valid deployment. This is a real concern for vsan esa versus osa compatibility, but it is not the most direct consequence of the specific condition. In this case, evaluate mirroring versus erasure coding and the effect on the affected workload or management path.

C:

A broken vSAN traffic path can partition storage membership and threaten VM object availability. This is a real concern for vsan cluster formation, but it is not the most direct consequence of the specific condition. In this case, evaluate mirroring versus erasure coding and the effect on the affected workload or management path.

D:

Exhausting the free-space buffer can block writes or slow recovery operations during an incident. This is a real concern for datastore capacity reserve, but it is not the most direct consequence of the specific condition. In this case, evaluate mirroring versus erasure coding and the effect on the affected workload or management path.

Question 120

An infrastructure specialist needs a focused first investigation before acting. A vSAN administrator wants to improve usable storage efficiency for a protected workload while meeting the selected fault-tolerance objective. Which investigation best distinguishes the suspected cause in this case?

  1. Check HBA zoning or NFS network reachability, datastore IDs and per-host mount state.
  2. Compare logical versus physical usage, workload compressibility and feature support for the installed architecture.
  3. Check the vSAN compatibility guide for ESA-certified devices, firmware, network and host platform.
  4. Inspect policy fault-tolerance method, required resources, current topology and the proposed object footprint.

Explanation

Correct Answer

D:

Inspect policy fault-tolerance method, required resources, current topology and the proposed object footprint. This inspection directly tests the suspected cause. The suitable response is: Compare supported erasure-coding and mirroring policy choices against resilience, capacity and cluster topology requirements. Expected resolution evidence: The final policy stays compliant and meets the capacity and performance targets after placement and health verification.

Incorrect Answers

A:

Check HBA zoning or NFS network reachability, datastore IDs and per-host mount state. That check targets shared datastore visibility and could be useful in a different incident. The first evidence needed here relates to mirroring versus erasure coding. First examine: Inspect policy fault-tolerance method, required resources, current topology and the proposed object footprint.

B:

Compare logical versus physical usage, workload compressibility and feature support for the installed architecture. That check targets deduplication and compression feasibility and could be useful in a different incident. The first evidence needed here relates to mirroring versus erasure coding. First examine: Inspect policy fault-tolerance method, required resources, current topology and the proposed object footprint.

C:

Check the vSAN compatibility guide for ESA-certified devices, firmware, network and host platform. That check targets vsan esa versus osa compatibility and could be useful in a different incident. The first evidence needed here relates to mirroring versus erasure coding. First examine: Inspect policy fault-tolerance method, required resources, current topology and the proposed object footprint.

VMware vSphere Foundation 9.0 Administrator (2V0-16.25) Practice Tests

Purchase Individually

  • Premium File

    60 Questions & Answers
    Last Update: Nov 12, 2026

    $76.99
    $69.99
  • Study Guide

    142 Pages

    $43.99
    $39.99

SPECIAL OFFER: GET 10% OFF
This is ONE TIME OFFER

You save
10%

Enter Your Email Address to Receive Your 10% Off Discount Code

SPECIAL OFFER: GET 10% OFF

You save
10%

Use Discount Code:

A confirmation link was sent to your e-mail.

Please check your mailbox for a message from support@examlabs.com and follow the directions.

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your email address below to get started with our interactive software demo of your free trial.

  • Realistic exam simulation and exam editor with preview functions
  • Whole exam in a single file with several different question types
  • Customizable exam-taking mode & detailed score reports