CompTIA Server+ Certification Exam SK0-005 Practice Test 11

Question 100

The server fault remains unresolved: A storage administrator presents a new SAN LUN but an application host cannot see it, and the proposed fix grants every host visibility to all storage array ports. Which evidence should be examined first to diagnose this particular issue?

  1. Inspect WWPN inventory, switch zoning sets, active fabric, array masking and host rescan results.
  2. Inspect enclosure inventory, fabric bay mapping, switch uplinks, virtual NIC profiles and host traffic traces.
  3. Inspect controller serial-to-slot map, drive enclosure indicators, array member state and rebuild progress.
  4. Inspect virtual media source, checksum, BMC access logs, boot order and rescue environment results.

Explanation

Correct Answer

A:

Inspect WWPN inventory, switch zoning sets, active fabric, array masking and host rescan results. These checks target the described failure in Correcting Fibre Channel zoning for a new database LUN. Appropriate response: Create the required vendor-recommended WWPN-based single-initiator zoning and array LUN masking for the authorized host. Success criteria: The intended HBA discovers only its approved LUNs and other fabric initiators remain unable to enumerate them.

Incorrect Answers

B:

Inspect enclosure inventory, fabric bay mapping, switch uplinks, virtual NIC profiles and host traffic traces. Those checks investigate Choosing blade enclosure networking rather than assuming standalone ports instead of the Correcting Fibre Channel zoning for a new database LUN failure. The focused investigation should be: Inspect WWPN inventory, switch zoning sets, active fabric, array masking and host rescan results.

C:

Inspect controller serial-to-slot map, drive enclosure indicators, array member state and rebuild progress. Those checks investigate Repairing a degraded RAID 5 without pulling the wrong drive instead of the Correcting Fibre Channel zoning for a new database LUN failure. The focused investigation should be: Inspect WWPN inventory, switch zoning sets, active fabric, array masking and host rescan results.

D:

Inspect virtual media source, checksum, BMC access logs, boot order and rescue environment results. Those checks investigate Rebinding virtual media for an authorized remote OS installation instead of the Correcting Fibre Channel zoning for a new database LUN failure. The focused investigation should be: Inspect WWPN inventory, switch zoning sets, active fabric, array masking and host rescan results.

Question 101

A CompTIA Server+ SK0-005 administrator reviews this production scenario: A research department needs simultaneous shared document access from multiple Linux servers, but engineers allocate an unclustered iSCSI block LUN and mount it read-write on all hosts. Which configuration or design change most directly solves the requirement?

  1. Calculate effective capacity after array redundancy, spare policy, filesystem overhead and vendor-supported usable-space reservations.
  2. Use an authorized shared file service such as NFS with suitable locking and permissions, or a supported clustered block filesystem if required.
  3. Use an authorized isolated BMC or iDRAC/iLO management path to inspect console state and perform only an approved recovery action.
  4. Provide an authorized rack console or managed KVM arrangement with documented secure access and cable mapping for emergency troubleshooting.

Explanation

Correct Answer

B:

Use an authorized shared file service such as NFS with suitable locking and permissions, or a supported clustered block filesystem if required. Technical basis: NAS exports file-system semantics; raw shared block storage requires separate coordinated filesystem ownership. Acceptance evidence: Two test servers create and modify distinct files concurrently without filesystem corruption and permissions hold. Deployment boundary: Confirm the server vendor hardware compatibility list, current operating system or hypervisor support, approved permissions, maintenance and backup processes before applying this educational example to production.

Incorrect Answers

A:

Calculate effective capacity after array redundancy, spare policy, filesystem overhead and vendor-supported usable-space reservations. This is a sensible intervention in the separate Calculating usable RAID storage with parity and spare overhead scenario. It does not resolve the present Choosing NFS shared files versus block SAN for application semantics requirement. For the current problem, use: Use an authorized shared file service such as NFS with suitable locking and permissions, or a supported clustered block filesystem if required.

C:

Use an authorized isolated BMC or iDRAC/iLO management path to inspect console state and perform only an approved recovery action. This is a sensible intervention in the separate Recovering a headless server through isolated out-of-band management scenario. It does not resolve the present Choosing NFS shared files versus block SAN for application semantics requirement. For the current problem, use: Use an authorized shared file service such as NFS with suitable locking and permissions, or a supported clustered block filesystem if required.

D:

Provide an authorized rack console or managed KVM arrangement with documented secure access and cable mapping for emergency troubleshooting. This is a sensible intervention in the separate Using a dedicated KVM path for shared emergency administration scenario. It does not resolve the present Choosing NFS shared files versus block SAN for application semantics requirement. For the current problem, use: Use an authorized shared file service such as NFS with suitable locking and permissions, or a supported clustered block filesystem if required.

Question 102

During a CompTIA Server+ incident recovery verification, the team observes: A research department needs simultaneous shared document access from multiple Linux servers, but engineers allocate an unclustered iSCSI block LUN and mount it read-write on all hosts. Which result is the most convincing evidence of the required outcome?

  1. Two test servers create and modify distinct files concurrently without filesystem corruption and permissions hold.
  2. A test rebuild after disk loss and a separate restore of a deleted file both succeed without relying on the original array copy.
  3. An authorized operator can view the target server's POST or firmware screen without disturbing other hosts or exposing management credentials.
  4. After an extended unplugged period, system clock and boot-order settings remain stable and the OS loads normally.

Explanation

Correct Answer

A:

Two test servers create and modify distinct files concurrently without filesystem corruption and permissions hold. This directly verifies Choosing NFS shared files versus block SAN for application semantics. Required action: Use an authorized shared file service such as NFS with suitable locking and permissions, or a supported clustered block filesystem if required. Why it is a suitable test: NAS exports file-system semantics; raw shared block storage requires separate coordinated filesystem ownership.

Incorrect Answers

B:

A test rebuild after disk loss and a separate restore of a deleted file both succeed without relying on the original array copy. This verifies the separate Distinguishing RAID 6 redundancy from two independent backups situation rather than Choosing NFS shared files versus block SAN for application semantics. The decisive outcome here is: Two test servers create and modify distinct files concurrently without filesystem corruption and permissions hold.

C:

An authorized operator can view the target server's POST or firmware screen without disturbing other hosts or exposing management credentials. This verifies the separate Using a dedicated KVM path for shared emergency administration situation rather than Choosing NFS shared files versus block SAN for application semantics. The decisive outcome here is: Two test servers create and modify distinct files concurrently without filesystem corruption and permissions hold.

D:

After an extended unplugged period, system clock and boot-order settings remain stable and the OS loads normally. This verifies the separate Replacing a CMOS battery while preserving critical firmware settings situation rather than Choosing NFS shared files versus block SAN for application semantics. The decisive outcome here is: Two test servers create and modify distinct files concurrently without filesystem corruption and permissions hold.

Question 103

A server administrator explains the technical behavior behind this situation: A research department needs simultaneous shared document access from multiple Linux servers, but engineers allocate an unclustered iSCSI block LUN and mount it read-write on all hosts. Which technical principle most directly explains the correct approach?

  1. NAS exports file-system semantics; raw shared block storage requires separate coordinated filesystem ownership.
  2. Fibre Channel fabric zoning and storage array masking are separate access boundaries for presented block devices.
  3. Firmware dependencies can span BIOS, storage, network adapters and BMC and need coordinated compatible revisions.
  4. Blade chassis share power, cooling and network switching, so blade connectivity follows enclosure backplane and interconnect configuration.

Explanation

Correct Answer

A:

NAS exports file-system semantics; raw shared block storage requires separate coordinated filesystem ownership. This is the governing technical explanation for Choosing NFS shared files versus block SAN for application semantics. Correct configuration: Use an authorized shared file service such as NFS with suitable locking and permissions, or a supported clustered block filesystem if required. Observable outcome: Two test servers create and modify distinct files concurrently without filesystem corruption and permissions hold.

Incorrect Answers

B:

Fibre Channel fabric zoning and storage array masking are separate access boundaries for presented block devices. That principle describes Correcting Fibre Channel zoning for a new database LUN, not the mechanism that governs Choosing NFS shared files versus block SAN for application semantics. The relevant principle is: NAS exports file-system semantics; raw shared block storage requires separate coordinated filesystem ownership.

C:

Firmware dependencies can span BIOS, storage, network adapters and BMC and need coordinated compatible revisions. That principle describes Installing server firmware without skipping compatibility sequencing, not the mechanism that governs Choosing NFS shared files versus block SAN for application semantics. The relevant principle is: NAS exports file-system semantics; raw shared block storage requires separate coordinated filesystem ownership.

D:

Blade chassis share power, cooling and network switching, so blade connectivity follows enclosure backplane and interconnect configuration. That principle describes Choosing blade enclosure networking rather than assuming standalone ports, not the mechanism that governs Choosing NFS shared files versus block SAN for application semantics. The relevant principle is: NAS exports file-system semantics; raw shared block storage requires separate coordinated filesystem ownership.

Question 104

The server team omits a necessary safeguard. A research department needs simultaneous shared document access from multiple Linux servers, but engineers allocate an unclustered iSCSI block LUN and mount it read-write on all hosts. Which resulting operational or security exposure is the most direct?

  1. A cheap high-capacity array can be unusably slow for metadata despite ample free space.
  2. Removing multiple modules can exceed thermal margins and force a server shutdown or hardware damage.
  3. A failed common PDU can shut down both nominally redundant supplies during an accounting deadline.
  4. Mounting a normal local filesystem on one LUN from multiple hosts can silently corrupt metadata.

Explanation

Correct Answer

D:

Mounting a normal local filesystem on one LUN from multiple hosts can silently corrupt metadata. This is the central risk in Choosing NFS shared files versus block SAN for application semantics. Appropriate safeguard: Use an authorized shared file service such as NFS with suitable locking and permissions, or a supported clustered block filesystem if required. Evidence the safeguard works: Two test servers create and modify distinct files concurrently without filesystem corruption and permissions hold.

Incorrect Answers

A:

A cheap high-capacity array can be unusably slow for metadata despite ample free space. This exposure applies to Sizing HDD spindle performance for a streaming workload, not the direct consequence of Choosing NFS shared files versus block SAN for application semantics. The actual case-specific risk is: Mounting a normal local filesystem on one LUN from multiple hosts can silently corrupt metadata.

B:

Removing multiple modules can exceed thermal margins and force a server shutdown or hardware damage. This exposure applies to Choosing a supported hot-swap fan repair under load, not the direct consequence of Choosing NFS shared files versus block SAN for application semantics. The actual case-specific risk is: Mounting a normal local filesystem on one LUN from multiple hosts can silently corrupt metadata.

C:

A failed common PDU can shut down both nominally redundant supplies during an accounting deadline. This exposure applies to Separating two server power supplies across failure domains, not the direct consequence of Choosing NFS shared files versus block SAN for application semantics. The actual case-specific risk is: Mounting a normal local filesystem on one LUN from multiple hosts can silently corrupt metadata.

Question 105

The server fault remains unresolved: A research department needs simultaneous shared document access from multiple Linux servers, but engineers allocate an unclustered iSCSI block LUN and mount it read-write on all hosts. Which evidence should be examined first to diagnose this particular issue?

  1. Inspect drive count, capacity, RAID layout, hot-spare assignment, filesystem reservations and usage forecast.
  2. Inspect application file semantics, NFS export options, LUN mappings, filesystem type and concurrent write tests.
  3. Inspect console-server ACLs, SSH or TLS access, port mapping, audit trail and recovery tests.
  4. Inspect PSU input readings, PDU outlets, breaker mappings, UPS sources, circuit capacities and failover test logs.

Explanation

Correct Answer

B:

Inspect application file semantics, NFS export options, LUN mappings, filesystem type and concurrent write tests. These checks target the described failure in Choosing NFS shared files versus block SAN for application semantics. Appropriate response: Use an authorized shared file service such as NFS with suitable locking and permissions, or a supported clustered block filesystem if required. Success criteria: Two test servers create and modify distinct files concurrently without filesystem corruption and permissions hold.

Incorrect Answers

A:

Inspect drive count, capacity, RAID layout, hot-spare assignment, filesystem reservations and usage forecast. Those checks investigate Calculating usable RAID storage with parity and spare overhead instead of the Choosing NFS shared files versus block SAN for application semantics failure. The focused investigation should be: Inspect application file semantics, NFS export options, LUN mappings, filesystem type and concurrent write tests.

C:

Inspect console-server ACLs, SSH or TLS access, port mapping, audit trail and recovery tests. Those checks investigate Isolating serial console paths for legacy network appliances instead of the Choosing NFS shared files versus block SAN for application semantics failure. The focused investigation should be: Inspect application file semantics, NFS export options, LUN mappings, filesystem type and concurrent write tests.

D:

Inspect PSU input readings, PDU outlets, breaker mappings, UPS sources, circuit capacities and failover test logs. Those checks investigate Separating two server power supplies across failure domains instead of the Choosing NFS shared files versus block SAN for application semantics failure. The focused investigation should be: Inspect application file semantics, NFS export options, LUN mappings, filesystem type and concurrent write tests.

Question 106

A CompTIA Server+ SK0-005 administrator reviews this production scenario: A video archive requires 40 TB usable but procurement orders exactly 40 TB raw across RAID 6 drives, ignoring two parity members and a hot spare. Which configuration or design change most directly solves the requirement?

  1. Use an authorized shared file service such as NFS with suitable locking and permissions, or a supported clustered block filesystem if required.
  2. Check vendor redundancy mode and each supply's load capacity, then replace the failed or intended unit under a documented one-supply maintenance window.
  3. Move the heavy chassis to approved lower rack units after facilities verifies rated floor capacity and the vendor's rail and lifting requirements.
  4. Calculate effective capacity after array redundancy, spare policy, filesystem overhead and vendor-supported usable-space reservations.

Explanation

Correct Answer

D:

Calculate effective capacity after array redundancy, spare policy, filesystem overhead and vendor-supported usable-space reservations. Technical basis: Raw drive capacity is not equal to usable protected volume capacity when parity, mirroring and spares consume space. Acceptance evidence: An allocation worksheet and provisioned datastore both show at least the approved usable capacity with reserve headroom. Deployment boundary: Confirm the server vendor hardware compatibility list, current operating system or hypervisor support, approved permissions, maintenance and backup processes before applying this educational example to production.

Incorrect Answers

A:

Use an authorized shared file service such as NFS with suitable locking and permissions, or a supported clustered block filesystem if required. This is a sensible intervention in the separate Choosing NFS shared files versus block SAN for application semantics scenario. It does not resolve the present Calculating usable RAID storage with parity and spare overhead requirement. For the current problem, use: Calculate effective capacity after array redundancy, spare policy, filesystem overhead and vendor-supported usable-space reservations.

B:

Check vendor redundancy mode and each supply's load capacity, then replace the failed or intended unit under a documented one-supply maintenance window. This is a sensible intervention in the separate Handling a hot-swappable PSU replacement without common-feed outage scenario. It does not resolve the present Calculating usable RAID storage with parity and spare overhead requirement. For the current problem, use: Calculate effective capacity after array redundancy, spare policy, filesystem overhead and vendor-supported usable-space reservations.

C:

Move the heavy chassis to approved lower rack units after facilities verifies rated floor capacity and the vendor's rail and lifting requirements. This is a sensible intervention in the separate Rack floor-loading calculation before mounting dense storage arrays scenario. It does not resolve the present Calculating usable RAID storage with parity and spare overhead requirement. For the current problem, use: Calculate effective capacity after array redundancy, spare policy, filesystem overhead and vendor-supported usable-space reservations.

Question 107

During a CompTIA Server+ incident recovery verification, the team observes: A video archive requires 40 TB usable but procurement orders exactly 40 TB raw across RAID 6 drives, ignoring two parity members and a hot spare. Which result is the most convincing evidence of the required outcome?

  1. A controlled switch or target-port failure preserves datastore I/O via the eligible remaining session without path duplication.
  2. An allocation worksheet and provisioned datastore both show at least the approved usable capacity with reserve headroom.
  3. The NIC enumerates at expected PCIe link width and transports the approved test workload without link or bus bottlenecks.
  4. The server boots the authorized rescue media without accessing an unapproved public share or changing production LUN content.

Explanation

Correct Answer

B:

An allocation worksheet and provisioned datastore both show at least the approved usable capacity with reserve headroom. This directly verifies Calculating usable RAID storage with parity and spare overhead. Required action: Calculate effective capacity after array redundancy, spare policy, filesystem overhead and vendor-supported usable-space reservations. Why it is a suitable test: Raw drive capacity is not equal to usable protected volume capacity when parity, mirroring and spares consume space.

Incorrect Answers

A:

A controlled switch or target-port failure preserves datastore I/O via the eligible remaining session without path duplication. This verifies the separate Configuring iSCSI storage multipathing over independent networks situation rather than Calculating usable RAID storage with parity and spare overhead. The decisive outcome here is: An allocation worksheet and provisioned datastore both show at least the approved usable capacity with reserve headroom.

C:

The NIC enumerates at expected PCIe link width and transports the approved test workload without link or bus bottlenecks. This verifies the separate Planning 10-gigabit NIC expansion without ignoring chassis buses situation rather than Calculating usable RAID storage with parity and spare overhead. The decisive outcome here is: An allocation worksheet and provisioned datastore both show at least the approved usable capacity with reserve headroom.

D:

The server boots the authorized rescue media without accessing an unapproved public share or changing production LUN content. This verifies the separate Rebinding virtual media for an authorized remote OS installation situation rather than Calculating usable RAID storage with parity and spare overhead. The decisive outcome here is: An allocation worksheet and provisioned datastore both show at least the approved usable capacity with reserve headroom.

Question 108

A server administrator explains the technical behavior behind this situation: A video archive requires 40 TB usable but procurement orders exactly 40 TB raw across RAID 6 drives, ignoring two parity members and a hot spare. Which technical principle most directly explains the correct approach?

  1. RAID 10 stripes across mirrored disk groups, reducing parity write overhead while retaining defined drive redundancy.
  2. Raw drive capacity is not equal to usable protected volume capacity when parity, mirroring and spares consume space.
  3. Hot-swappable power requires enough remaining capacity and correct upstream feeds during the service interval.
  4. Two PSUs provide resilience only when upstream delivery avoids the same unprotected circuit or device.

Explanation

Correct Answer

B:

Raw drive capacity is not equal to usable protected volume capacity when parity, mirroring and spares consume space. This is the governing technical explanation for Calculating usable RAID storage with parity and spare overhead. Correct configuration: Calculate effective capacity after array redundancy, spare policy, filesystem overhead and vendor-supported usable-space reservations. Observable outcome: An allocation worksheet and provisioned datastore both show at least the approved usable capacity with reserve headroom.

Incorrect Answers

A:

RAID 10 stripes across mirrored disk groups, reducing parity write overhead while retaining defined drive redundancy. That principle describes Selecting RAID 10 for low-latency transactional writes, not the mechanism that governs Calculating usable RAID storage with parity and spare overhead. The relevant principle is: Raw drive capacity is not equal to usable protected volume capacity when parity, mirroring and spares consume space.

C:

Hot-swappable power requires enough remaining capacity and correct upstream feeds during the service interval. That principle describes Handling a hot-swappable PSU replacement without common-feed outage, not the mechanism that governs Calculating usable RAID storage with parity and spare overhead. The relevant principle is: Raw drive capacity is not equal to usable protected volume capacity when parity, mirroring and spares consume space.

D:

Two PSUs provide resilience only when upstream delivery avoids the same unprotected circuit or device. That principle describes Separating two server power supplies across failure domains, not the mechanism that governs Calculating usable RAID storage with parity and spare overhead. The relevant principle is: Raw drive capacity is not equal to usable protected volume capacity when parity, mirroring and spares consume space.

Question 109

The server team omits a necessary safeguard. A video archive requires 40 TB usable but procurement orders exactly 40 TB raw across RAID 6 drives, ignoring two parity members and a hot spare. Which resulting operational or security exposure is the most direct?

  1. Read-optimized drives under continuous writes may exhaust endurance long before nominal capacity is used.
  2. Capacity shortfall can block production ingest despite purchase orders showing the nominal required terabytes.
  3. An exposed terminal server can enable configuration theft or disruption across many network devices.
  4. Improper handling may create latent failures that emerge after the production change window closes.

Explanation

Correct Answer

B:

Capacity shortfall can block production ingest despite purchase orders showing the nominal required terabytes. This is the central risk in Calculating usable RAID storage with parity and spare overhead. Appropriate safeguard: Calculate effective capacity after array redundancy, spare policy, filesystem overhead and vendor-supported usable-space reservations. Evidence the safeguard works: An allocation worksheet and provisioned datastore both show at least the approved usable capacity with reserve headroom.

Incorrect Answers

A:

Read-optimized drives under continuous writes may exhaust endurance long before nominal capacity is used. This exposure applies to Managing write-intensive SSD wear rather than capacity only, not the direct consequence of Calculating usable RAID storage with parity and spare overhead. The actual case-specific risk is: Capacity shortfall can block production ingest despite purchase orders showing the nominal required terabytes.

C:

An exposed terminal server can enable configuration theft or disruption across many network devices. This exposure applies to Isolating serial console paths for legacy network appliances, not the direct consequence of Calculating usable RAID storage with parity and spare overhead. The actual case-specific risk is: Capacity shortfall can block production ingest despite purchase orders showing the nominal required terabytes.

D:

Improper handling may create latent failures that emerge after the production change window closes. This exposure applies to Preventing static damage while replacing a riser card, not the direct consequence of Calculating usable RAID storage with parity and spare overhead. The actual case-specific risk is: Capacity shortfall can block production ingest despite purchase orders showing the nominal required terabytes.

Question 110

The server fault remains unresolved: A video archive requires 40 TB usable but procurement orders exactly 40 TB raw across RAID 6 drives, ignoring two parity members and a hot spare. Which evidence should be examined first to diagnose this particular issue?

  1. Inspect application file semantics, NFS export options, LUN mappings, filesystem type and concurrent write tests.
  2. Inspect firmware boot mode, GPT layout, EFI boot entries, secure boot state and storage detection.
  3. Inspect KVM port assignments, physical console access control, cabling labels and an isolated BIOS access test.
  4. Inspect drive count, capacity, RAID layout, hot-spare assignment, filesystem reservations and usage forecast.

Explanation

Correct Answer

D:

Inspect drive count, capacity, RAID layout, hot-spare assignment, filesystem reservations and usage forecast. These checks target the described failure in Calculating usable RAID storage with parity and spare overhead. Appropriate response: Calculate effective capacity after array redundancy, spare policy, filesystem overhead and vendor-supported usable-space reservations. Success criteria: An allocation worksheet and provisioned datastore both show at least the approved usable capacity with reserve headroom.

Incorrect Answers

A:

Inspect application file semantics, NFS export options, LUN mappings, filesystem type and concurrent write tests. Those checks investigate Choosing NFS shared files versus block SAN for application semantics instead of the Calculating usable RAID storage with parity and spare overhead failure. The focused investigation should be: Inspect drive count, capacity, RAID layout, hot-spare assignment, filesystem reservations and usage forecast.

B:

Inspect firmware boot mode, GPT layout, EFI boot entries, secure boot state and storage detection. Those checks investigate Correcting UEFI boot mode after boot disk replacement instead of the Calculating usable RAID storage with parity and spare overhead failure. The focused investigation should be: Inspect drive count, capacity, RAID layout, hot-spare assignment, filesystem reservations and usage forecast.

C:

Inspect KVM port assignments, physical console access control, cabling labels and an isolated BIOS access test. Those checks investigate Using a dedicated KVM path for shared emergency administration instead of the Calculating usable RAID storage with parity and spare overhead failure. The focused investigation should be: Inspect drive count, capacity, RAID layout, hot-spare assignment, filesystem reservations and usage forecast.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Purchase Individually

  • Premium File

    617 Questions & Answers
    Last Update: Nov 9, 2026

    $76.99
    $69.99
  • Training Course

    139 Lectures

    $43.99
    $39.99
  • Study Guide

    533 Pages

    $43.99
    $39.99

SPECIAL OFFER: GET 10% OFF
This is ONE TIME OFFER

You save
10%

Enter Your Email Address to Receive Your 10% Off Discount Code

SPECIAL OFFER: GET 10% OFF

You save
10%

Use Discount Code:

A confirmation link was sent to your e-mail.

Please check your mailbox for a message from support@examlabs.com and follow the directions.

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your email address below to get started with our interactive software demo of your free trial.

  • Realistic exam simulation and exam editor with preview functions
  • Whole exam in a single file with several different question types
  • Customizable exam-taking mode & detailed score reports