CompTIA Server+ Certification Exam SK0-005 Practice Test 16

Question 150

The server fault remains unresolved: A server facility operates old appliances with serial consoles, but engineers attach USB-to-serial adapters to the public data network to allow unmanaged remote access. Which evidence should be examined first to diagnose this particular issue?

  1. Inspect BMC VLAN, access audit, host heartbeat, console capture and approved recovery record.
  2. Inspect KVM port assignments, physical console access control, cabling labels and an isolated BIOS access test.
  3. Inspect application file semantics, NFS export options, LUN mappings, filesystem type and concurrent write tests.
  4. Inspect console-server ACLs, SSH or TLS access, port mapping, audit trail and recovery tests.

Explanation

Correct Answer

D:

Inspect console-server ACLs, SSH or TLS access, port mapping, audit trail and recovery tests. These checks target the described failure in Isolating serial console paths for legacy network appliances. Appropriate response: Place supported serial console servers on an isolated authenticated management network with logged operator access and device labeling. Success criteria: Only authorized administrators reach the correct appliance console and failed production Ethernet does not remove access.

Incorrect Answers

A:

Inspect BMC VLAN, access audit, host heartbeat, console capture and approved recovery record. Those checks investigate Recovering a headless server through isolated out-of-band management instead of the Isolating serial console paths for legacy network appliances failure. The focused investigation should be: Inspect console-server ACLs, SSH or TLS access, port mapping, audit trail and recovery tests.

B:

Inspect KVM port assignments, physical console access control, cabling labels and an isolated BIOS access test. Those checks investigate Using a dedicated KVM path for shared emergency administration instead of the Isolating serial console paths for legacy network appliances failure. The focused investigation should be: Inspect console-server ACLs, SSH or TLS access, port mapping, audit trail and recovery tests.

C:

Inspect application file semantics, NFS export options, LUN mappings, filesystem type and concurrent write tests. Those checks investigate Choosing NFS shared files versus block SAN for application semantics instead of the Isolating serial console paths for legacy network appliances failure. The focused investigation should be: Inspect console-server ACLs, SSH or TLS access, port mapping, audit trail and recovery tests.

Question 151

A CompTIA Server+ SK0-005 administrator reviews this production scenario: A hardware technician replaces one failed DIMM in a two-socket host but fills a spare slot on the wrong CPU channel, causing reduced usable memory despite healthy modules. Which configuration or design change most directly solves the requirement?

  1. Follow the chassis memory population diagram and place HCL-compatible modules on required channels and processor nodes.
  2. Follow the approved firmware compatibility matrix and staged maintenance process, updating components in the required order with rollback evidence.
  3. Select HCL-supported CPU and DIMM combinations with required BIOS revision and documented channel population order before changing production hardware.
  4. Select server-HCL compatible drives and the required SAS HBA, backplane and multipath topology for the workload.

Explanation

Correct Answer

A:

Follow the chassis memory population diagram and place HCL-compatible modules on required channels and processor nodes. Technical basis: NUMA and memory channel population rules influence capacity recognition and bandwidth on multi-socket servers. Acceptance evidence: POST reports intended total memory and channel mode, and burn-in testing clears ECC or placement warnings. Deployment boundary: Confirm the server vendor hardware compatibility list, current operating system or hypervisor support, approved permissions, maintenance and backup processes before applying this educational example to production.

Incorrect Answers

B:

Follow the approved firmware compatibility matrix and staged maintenance process, updating components in the required order with rollback evidence. This is a sensible intervention in the separate Installing server firmware without skipping compatibility sequencing scenario. It does not resolve the present Choosing DIMM slot placement for replacement memory module requirement. For the current problem, use: Follow the chassis memory population diagram and place HCL-compatible modules on required channels and processor nodes.

C:

Select HCL-supported CPU and DIMM combinations with required BIOS revision and documented channel population order before changing production hardware. This is a sensible intervention in the separate Validating CPU and memory platform compatibility before refresh scenario. It does not resolve the present Choosing DIMM slot placement for replacement memory module requirement. For the current problem, use: Follow the chassis memory population diagram and place HCL-compatible modules on required channels and processor nodes.

D:

Select server-HCL compatible drives and the required SAS HBA, backplane and multipath topology for the workload. This is a sensible intervention in the separate Matching SAS drives with supported HBA and backplane scenario. It does not resolve the present Choosing DIMM slot placement for replacement memory module requirement. For the current problem, use: Follow the chassis memory population diagram and place HCL-compatible modules on required channels and processor nodes.

Question 152

During a CompTIA Server+ incident recovery verification, the team observes: A hardware technician replaces one failed DIMM in a two-socket host but fills a spare slot on the wrong CPU channel, causing reduced usable memory despite healthy modules. Which result is the most convincing evidence of the required outcome?

  1. Power telemetry confirms the surviving feed supports peak load and no enclosure reset occurs during authorized replacement.
  2. The correct replacement disk rejoins the array and rebuild completes with no unexpected second member removal.
  3. POST reports intended total memory and channel mode, and burn-in testing clears ECC or placement warnings.
  4. The new blade reaches its approved management and data networks through the intended virtual ports and redundant chassis fabrics.

Explanation

Correct Answer

C:

POST reports intended total memory and channel mode, and burn-in testing clears ECC or placement warnings. This directly verifies Choosing DIMM slot placement for replacement memory module. Required action: Follow the chassis memory population diagram and place HCL-compatible modules on required channels and processor nodes. Why it is a suitable test: NUMA and memory channel population rules influence capacity recognition and bandwidth on multi-socket servers.

Incorrect Answers

A:

Power telemetry confirms the surviving feed supports peak load and no enclosure reset occurs during authorized replacement. This verifies the separate Handling a hot-swappable PSU replacement without common-feed outage situation rather than Choosing DIMM slot placement for replacement memory module. The decisive outcome here is: POST reports intended total memory and channel mode, and burn-in testing clears ECC or placement warnings.

B:

The correct replacement disk rejoins the array and rebuild completes with no unexpected second member removal. This verifies the separate Repairing a degraded RAID 5 without pulling the wrong drive situation rather than Choosing DIMM slot placement for replacement memory module. The decisive outcome here is: POST reports intended total memory and channel mode, and burn-in testing clears ECC or placement warnings.

D:

The new blade reaches its approved management and data networks through the intended virtual ports and redundant chassis fabrics. This verifies the separate Choosing blade enclosure networking rather than assuming standalone ports situation rather than Choosing DIMM slot placement for replacement memory module. The decisive outcome here is: POST reports intended total memory and channel mode, and burn-in testing clears ECC or placement warnings.

Question 153

A server administrator explains the technical behavior behind this situation: A hardware technician replaces one failed DIMM in a two-socket host but fills a spare slot on the wrong CPU channel, causing reduced usable memory despite healthy modules. Which technical principle most directly explains the correct approach?

  1. Hot-swappable power requires enough remaining capacity and correct upstream feeds during the service interval.
  2. NUMA and memory channel population rules influence capacity recognition and bandwidth on multi-socket servers.
  3. Server component compatibility depends on firmware, socket generation, channel wiring and manufacturer-qualified module characteristics.
  4. Raw drive capacity is not equal to usable protected volume capacity when parity, mirroring and spares consume space.

Explanation

Correct Answer

B:

NUMA and memory channel population rules influence capacity recognition and bandwidth on multi-socket servers. This is the governing technical explanation for Choosing DIMM slot placement for replacement memory module. Correct configuration: Follow the chassis memory population diagram and place HCL-compatible modules on required channels and processor nodes. Observable outcome: POST reports intended total memory and channel mode, and burn-in testing clears ECC or placement warnings.

Incorrect Answers

A:

Hot-swappable power requires enough remaining capacity and correct upstream feeds during the service interval. That principle describes Handling a hot-swappable PSU replacement without common-feed outage, not the mechanism that governs Choosing DIMM slot placement for replacement memory module. The relevant principle is: NUMA and memory channel population rules influence capacity recognition and bandwidth on multi-socket servers.

C:

Server component compatibility depends on firmware, socket generation, channel wiring and manufacturer-qualified module characteristics. That principle describes Validating CPU and memory platform compatibility before refresh, not the mechanism that governs Choosing DIMM slot placement for replacement memory module. The relevant principle is: NUMA and memory channel population rules influence capacity recognition and bandwidth on multi-socket servers.

D:

Raw drive capacity is not equal to usable protected volume capacity when parity, mirroring and spares consume space. That principle describes Calculating usable RAID storage with parity and spare overhead, not the mechanism that governs Choosing DIMM slot placement for replacement memory module. The relevant principle is: NUMA and memory channel population rules influence capacity recognition and bandwidth on multi-socket servers.

Question 154

The server team omits a necessary safeguard. A hardware technician replaces one failed DIMM in a two-socket host but fills a spare slot on the wrong CPU channel, causing reduced usable memory despite healthy modules. Which resulting operational or security exposure is the most direct?

  1. Incorrect boot-mode changes can turn a healthy boot partition into an apparently missing operating system.
  2. Unsupported DIMMs or CPUs can prevent POST or run degraded and generate recurring memory errors.
  3. Wrong-drive replacement during degraded service can render the entire file volume inaccessible.
  4. Incorrect seating or channel placement can degrade server performance or leave memory offline.

Explanation

Correct Answer

D:

Incorrect seating or channel placement can degrade server performance or leave memory offline. This is the central risk in Choosing DIMM slot placement for replacement memory module. Appropriate safeguard: Follow the chassis memory population diagram and place HCL-compatible modules on required channels and processor nodes. Evidence the safeguard works: POST reports intended total memory and channel mode, and burn-in testing clears ECC or placement warnings.

Incorrect Answers

A:

Incorrect boot-mode changes can turn a healthy boot partition into an apparently missing operating system. This exposure applies to Correcting UEFI boot mode after boot disk replacement, not the direct consequence of Choosing DIMM slot placement for replacement memory module. The actual case-specific risk is: Incorrect seating or channel placement can degrade server performance or leave memory offline.

B:

Unsupported DIMMs or CPUs can prevent POST or run degraded and generate recurring memory errors. This exposure applies to Validating CPU and memory platform compatibility before refresh, not the direct consequence of Choosing DIMM slot placement for replacement memory module. The actual case-specific risk is: Incorrect seating or channel placement can degrade server performance or leave memory offline.

C:

Wrong-drive replacement during degraded service can render the entire file volume inaccessible. This exposure applies to Repairing a degraded RAID 5 without pulling the wrong drive, not the direct consequence of Choosing DIMM slot placement for replacement memory module. The actual case-specific risk is: Incorrect seating or channel placement can degrade server performance or leave memory offline.

Question 155

The server fault remains unresolved: A hardware technician replaces one failed DIMM in a two-socket host but fills a spare slot on the wrong CPU channel, causing reduced usable memory despite healthy modules. Which evidence should be examined first to diagnose this particular issue?

  1. Inspect motherboard DIMM chart, slot LEDs, BIOS memory status and postrepair diagnostics.
  2. Inspect motherboard revision, supported CPU stepping, BIOS version, DIMM part numbers, population chart and burn-in logs.
  3. Inspect firmware clock drift, battery voltage, boot order changes, event history and postreplacement power-cycle tests.
  4. Inspect controller cache mode, battery health, event logs, drive status and application consistency checks.

Explanation

Correct Answer

A:

Inspect motherboard DIMM chart, slot LEDs, BIOS memory status and postrepair diagnostics. These checks target the described failure in Choosing DIMM slot placement for replacement memory module. Appropriate response: Follow the chassis memory population diagram and place HCL-compatible modules on required channels and processor nodes. Success criteria: POST reports intended total memory and channel mode, and burn-in testing clears ECC or placement warnings.

Incorrect Answers

B:

Inspect motherboard revision, supported CPU stepping, BIOS version, DIMM part numbers, population chart and burn-in logs. Those checks investigate Validating CPU and memory platform compatibility before refresh instead of the Choosing DIMM slot placement for replacement memory module failure. The focused investigation should be: Inspect motherboard DIMM chart, slot LEDs, BIOS memory status and postrepair diagnostics.

C:

Inspect firmware clock drift, battery voltage, boot order changes, event history and postreplacement power-cycle tests. Those checks investigate Replacing a CMOS battery while preserving critical firmware settings instead of the Choosing DIMM slot placement for replacement memory module failure. The focused investigation should be: Inspect motherboard DIMM chart, slot LEDs, BIOS memory status and postrepair diagnostics.

D:

Inspect controller cache mode, battery health, event logs, drive status and application consistency checks. Those checks investigate Distinguishing an SSD caching fault from lost underlying data instead of the Choosing DIMM slot placement for replacement memory module failure. The focused investigation should be: Inspect motherboard DIMM chart, slot LEDs, BIOS memory status and postrepair diagnostics.

Question 156

A CompTIA Server+ SK0-005 administrator reviews this production scenario: An enterprise provisions management controllers with a shared default password identical to application administration credentials and exposes them to office clients. Which configuration or design change most directly solves the requirement?

  1. Place supported serial console servers on an isolated authenticated management network with logged operator access and device labeling.
  2. Configure supported initiator multipathing across segregated fabrics and independent array target ports with consistent access controls.
  3. Use unique protected BMC credentials, supported MFA or access gateway controls and a segregated management network for authorized administrators.
  4. Provide an authorized rack console or managed KVM arrangement with documented secure access and cable mapping for emergency troubleshooting.

Explanation

Correct Answer

C:

Use unique protected BMC credentials, supported MFA or access gateway controls and a segregated management network for authorized administrators. Technical basis: Hardware control accounts can operate below the OS security boundary and should not inherit broad application trust. Acceptance evidence: Audit and negative tests show only permitted management roles can invoke remote power and firmware operations. Deployment boundary: Confirm the server vendor hardware compatibility list, current operating system or hypervisor support, approved permissions, maintenance and backup processes before applying this educational example to production.

Incorrect Answers

A:

Place supported serial console servers on an isolated authenticated management network with logged operator access and device labeling. This is a sensible intervention in the separate Isolating serial console paths for legacy network appliances scenario. It does not resolve the present Separating BMC accounts from ordinary domain service identities requirement. For the current problem, use: Use unique protected BMC credentials, supported MFA or access gateway controls and a segregated management network for authorized administrators.

B:

Configure supported initiator multipathing across segregated fabrics and independent array target ports with consistent access controls. This is a sensible intervention in the separate Configuring iSCSI storage multipathing over independent networks scenario. It does not resolve the present Separating BMC accounts from ordinary domain service identities requirement. For the current problem, use: Use unique protected BMC credentials, supported MFA or access gateway controls and a segregated management network for authorized administrators.

D:

Provide an authorized rack console or managed KVM arrangement with documented secure access and cable mapping for emergency troubleshooting. This is a sensible intervention in the separate Using a dedicated KVM path for shared emergency administration scenario. It does not resolve the present Separating BMC accounts from ordinary domain service identities requirement. For the current problem, use: Use unique protected BMC credentials, supported MFA or access gateway controls and a segregated management network for authorized administrators.

Question 157

During a CompTIA Server+ incident recovery verification, the team observes: An enterprise provisions management controllers with a shared default password identical to application administration credentials and exposes them to office clients. Which result is the most convincing evidence of the required outcome?

  1. Remote console exposes the OS or POST failure and a scoped restart succeeds without opening management ports publicly.
  2. An authorized operator can view the target server's POST or firmware screen without disturbing other hosts or exposing management credentials.
  3. The storage controller discovers all intended disks on both approved paths and supports the specified fault operations.
  4. Audit and negative tests show only permitted management roles can invoke remote power and firmware operations.

Explanation

Correct Answer

D:

Audit and negative tests show only permitted management roles can invoke remote power and firmware operations. This directly verifies Separating BMC accounts from ordinary domain service identities. Required action: Use unique protected BMC credentials, supported MFA or access gateway controls and a segregated management network for authorized administrators. Why it is a suitable test: Hardware control accounts can operate below the OS security boundary and should not inherit broad application trust.

Incorrect Answers

A:

Remote console exposes the OS or POST failure and a scoped restart succeeds without opening management ports publicly. This verifies the separate Recovering a headless server through isolated out-of-band management situation rather than Separating BMC accounts from ordinary domain service identities. The decisive outcome here is: Audit and negative tests show only permitted management roles can invoke remote power and firmware operations.

B:

An authorized operator can view the target server's POST or firmware screen without disturbing other hosts or exposing management credentials. This verifies the separate Using a dedicated KVM path for shared emergency administration situation rather than Separating BMC accounts from ordinary domain service identities. The decisive outcome here is: Audit and negative tests show only permitted management roles can invoke remote power and firmware operations.

C:

The storage controller discovers all intended disks on both approved paths and supports the specified fault operations. This verifies the separate Matching SAS drives with supported HBA and backplane situation rather than Separating BMC accounts from ordinary domain service identities. The decisive outcome here is: Audit and negative tests show only permitted management roles can invoke remote power and firmware operations.

Question 158

A server administrator explains the technical behavior behind this situation: An enterprise provisions management controllers with a shared default password identical to application administration credentials and exposes them to office clients. Which technical principle most directly explains the correct approach?

  1. Out-of-band management operates separately from the guest OS network interface and can survive operating-system failure.
  2. Fibre Channel fabric zoning and storage array masking are separate access boundaries for presented block devices.
  3. Rack airflow orientation, containment and cable obstruction control where cold air reaches equipment rather than just room cooling setpoints.
  4. Hardware control accounts can operate below the OS security boundary and should not inherit broad application trust.

Explanation

Correct Answer

D:

Hardware control accounts can operate below the OS security boundary and should not inherit broad application trust. This is the governing technical explanation for Separating BMC accounts from ordinary domain service identities. Correct configuration: Use unique protected BMC credentials, supported MFA or access gateway controls and a segregated management network for authorized administrators. Observable outcome: Audit and negative tests show only permitted management roles can invoke remote power and firmware operations.

Incorrect Answers

A:

Out-of-band management operates separately from the guest OS network interface and can survive operating-system failure. That principle describes Recovering a headless server through isolated out-of-band management, not the mechanism that governs Separating BMC accounts from ordinary domain service identities. The relevant principle is: Hardware control accounts can operate below the OS security boundary and should not inherit broad application trust.

B:

Fibre Channel fabric zoning and storage array masking are separate access boundaries for presented block devices. That principle describes Correcting Fibre Channel zoning for a new database LUN, not the mechanism that governs Separating BMC accounts from ordinary domain service identities. The relevant principle is: Hardware control accounts can operate below the OS security boundary and should not inherit broad application trust.

C:

Rack airflow orientation, containment and cable obstruction control where cold air reaches equipment rather than just room cooling setpoints. That principle describes Correcting rack cooling when front-to-back airflow is blocked, not the mechanism that governs Separating BMC accounts from ordinary domain service identities. The relevant principle is: Hardware control accounts can operate below the OS security boundary and should not inherit broad application trust.

Question 159

The server team omits a necessary safeguard. An enterprise provisions management controllers with a shared default password identical to application administration credentials and exposes them to office clients. Which resulting operational or security exposure is the most direct?

  1. Removing multiple modules can exceed thermal margins and force a server shutdown or hardware damage.
  2. A failed common PDU can shut down both nominally redundant supplies during an accounting deadline.
  3. Compromising a shared BMC password may allow firmware tampering or remote shutdown of many servers.
  4. Ransomware or accidental deletion can remove the only usable data even when every parity disk is healthy.

Explanation

Correct Answer

C:

Compromising a shared BMC password may allow firmware tampering or remote shutdown of many servers. This is the central risk in Separating BMC accounts from ordinary domain service identities. Appropriate safeguard: Use unique protected BMC credentials, supported MFA or access gateway controls and a segregated management network for authorized administrators. Evidence the safeguard works: Audit and negative tests show only permitted management roles can invoke remote power and firmware operations.

Incorrect Answers

A:

Removing multiple modules can exceed thermal margins and force a server shutdown or hardware damage. This exposure applies to Choosing a supported hot-swap fan repair under load, not the direct consequence of Separating BMC accounts from ordinary domain service identities. The actual case-specific risk is: Compromising a shared BMC password may allow firmware tampering or remote shutdown of many servers.

B:

A failed common PDU can shut down both nominally redundant supplies during an accounting deadline. This exposure applies to Separating two server power supplies across failure domains, not the direct consequence of Separating BMC accounts from ordinary domain service identities. The actual case-specific risk is: Compromising a shared BMC password may allow firmware tampering or remote shutdown of many servers.

D:

Ransomware or accidental deletion can remove the only usable data even when every parity disk is healthy. This exposure applies to Distinguishing RAID 6 redundancy from two independent backups, not the direct consequence of Separating BMC accounts from ordinary domain service identities. The actual case-specific risk is: Compromising a shared BMC password may allow firmware tampering or remote shutdown of many servers.

Question 160

The server fault remains unresolved: An enterprise provisions management controllers with a shared default password identical to application administration credentials and exposes them to office clients. Which evidence should be examined first to diagnose this particular issue?

  1. Inspect release notes, current firmware inventory, dependency matrix, maintenance schedule and POST logs.
  2. Inspect ESD controls, service procedure, packaging, power isolation and post-change hardware event logs.
  3. Inspect WWPN inventory, switch zoning sets, active fabric, array masking and host rescan results.
  4. Inspect BMC account inventory, network restrictions, credential vault use and remote power event logs.

Explanation

Correct Answer

D:

Inspect BMC account inventory, network restrictions, credential vault use and remote power event logs. These checks target the described failure in Separating BMC accounts from ordinary domain service identities. Appropriate response: Use unique protected BMC credentials, supported MFA or access gateway controls and a segregated management network for authorized administrators. Success criteria: Audit and negative tests show only permitted management roles can invoke remote power and firmware operations.

Incorrect Answers

A:

Inspect release notes, current firmware inventory, dependency matrix, maintenance schedule and POST logs. Those checks investigate Installing server firmware without skipping compatibility sequencing instead of the Separating BMC accounts from ordinary domain service identities failure. The focused investigation should be: Inspect BMC account inventory, network restrictions, credential vault use and remote power event logs.

B:

Inspect ESD controls, service procedure, packaging, power isolation and post-change hardware event logs. Those checks investigate Preventing static damage while replacing a riser card instead of the Separating BMC accounts from ordinary domain service identities failure. The focused investigation should be: Inspect BMC account inventory, network restrictions, credential vault use and remote power event logs.

C:

Inspect WWPN inventory, switch zoning sets, active fabric, array masking and host rescan results. Those checks investigate Correcting Fibre Channel zoning for a new database LUN instead of the Separating BMC accounts from ordinary domain service identities failure. The focused investigation should be: Inspect BMC account inventory, network restrictions, credential vault use and remote power event logs.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Purchase Individually

  • Premium File

    617 Questions & Answers
    Last Update: Nov 9, 2026

    $76.99
    $69.99
  • Training Course

    139 Lectures

    $43.99
    $39.99
  • Study Guide

    533 Pages

    $43.99
    $39.99

SPECIAL OFFER: GET 10% OFF
This is ONE TIME OFFER

You save
10%

Enter Your Email Address to Receive Your 10% Off Discount Code

SPECIAL OFFER: GET 10% OFF

You save
10%

Use Discount Code:

A confirmation link was sent to your e-mail.

Please check your mailbox for a message from support@examlabs.com and follow the directions.

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your email address below to get started with our interactive software demo of your free trial.

  • Realistic exam simulation and exam editor with preview functions
  • Whole exam in a single file with several different question types
  • Customizable exam-taking mode & detailed score reports