CompTIA Server+ Certification Exam SK0-005 Practice Test 47

Question 460

The server fault remains unresolved: A small data center leaves UEFI setup and removable-media boot unrestricted on critical authentication servers after the disks are encrypted. Which evidence should be examined first to diagnose this particular issue?

  1. Inspect sshd configuration, sudoers, authorized keys, firewall restrictions and auth logs.
  2. Inspect backup copy locations, site risk assessment, transport security and off-site restore drill.
  3. Inspect hold authorization, preserved datasets, hashing, audit trail and storage access controls.
  4. Inspect UEFI security configuration, boot order, authorized recovery procedures and physical console audit.

Explanation

Correct Answer

D:

Inspect UEFI security configuration, boot order, authorized recovery procedures and physical console audit. These checks target the described failure in Protecting firmware boot settings against unauthorized physical modification. Appropriate response: Apply supported firmware administrator authentication and approved secure boot or boot-order restrictions with documented recovery escrow. Success criteria: An unprivileged console user cannot change boot sequence and authorized recovery access remains available when necessary.

Incorrect Answers

A:

Inspect sshd configuration, sudoers, authorized keys, firewall restrictions and auth logs. Those checks investigate Hardening remote administration by restricting SSH access instead of the Protecting firmware boot settings against unauthorized physical modification failure. The focused investigation should be: Inspect UEFI security configuration, boot order, authorized recovery procedures and physical console audit.

B:

Inspect backup copy locations, site risk assessment, transport security and off-site restore drill. Those checks investigate Choosing off-site copies for a flood-prone primary datacenter instead of the Protecting firmware boot settings against unauthorized physical modification failure. The focused investigation should be: Inspect UEFI security configuration, boot order, authorized recovery procedures and physical console audit.

C:

Inspect hold authorization, preserved datasets, hashing, audit trail and storage access controls. Those checks investigate Handling a legal hold without arbitrary deletion of security evidence instead of the Protecting firmware boot settings against unauthorized physical modification failure. The focused investigation should be: Inspect UEFI security configuration, boot order, authorized recovery procedures and physical console audit.

Question 461

A CompTIA Server+ SK0-005 administrator reviews this production scenario: A colocation suite uses a single badge reader and employees regularly hold its door for visitors, bypassing intended controlled entry records. Which configuration or design change most directly solves the requirement?

  1. Use approved locked cages or rack doors with escorted service procedures and media inventory accountability.
  2. Use approved split-control or dual-authorization procedures for sensitive key retrieval, rotation and irreversible destruction.
  3. Implement approved mantrap or access vestibule controls with anti-tailgating procedures and individual authorization tracking.
  4. Implement approved retention periods, legal-hold exceptions and documented deletion procedures for each protected dataset.

Explanation

Correct Answer

C:

Implement approved mantrap or access vestibule controls with anti-tailgating procedures and individual authorization tracking. Technical basis: Physical access controls must prevent unauthorized person-following as well as authenticate the badge holder. Acceptance evidence: A test visitor cannot enter unattended after another user badges in, and access logs reliably identify individual entrants. Deployment boundary: Confirm the server vendor hardware compatibility list, current operating system or hypervisor support, approved permissions, maintenance and backup processes before applying this educational example to production.

Incorrect Answers

A:

Use approved locked cages or rack doors with escorted service procedures and media inventory accountability. This is a sensible intervention in the separate Restricting removable server equipment through secured cages scenario. It does not resolve the present Implementing a vestibule for data hall entry instead of shared access cards requirement. For the current problem, use: Implement approved mantrap or access vestibule controls with anti-tailgating procedures and individual authorization tracking.

B:

Use approved split-control or dual-authorization procedures for sensitive key retrieval, rotation and irreversible destruction. This is a sensible intervention in the separate Applying two-person integrity to high-value encryption keys scenario. It does not resolve the present Implementing a vestibule for data hall entry instead of shared access cards requirement. For the current problem, use: Implement approved mantrap or access vestibule controls with anti-tailgating procedures and individual authorization tracking.

D:

Implement approved retention periods, legal-hold exceptions and documented deletion procedures for each protected dataset. This is a sensible intervention in the separate Applying retention policy to encrypted archive storage scenario. It does not resolve the present Implementing a vestibule for data hall entry instead of shared access cards requirement. For the current problem, use: Implement approved mantrap or access vestibule controls with anti-tailgating procedures and individual authorization tracking.

Question 462

During a CompTIA Server+ incident recovery verification, the team observes: A colocation suite uses a single badge reader and employees regularly hold its door for visitors, bypassing intended controlled entry records. Which result is the most convincing evidence of the required outcome?

  1. An approved inspection confirms detection, alarm, suppression and safe human evacuation behavior under a supervised test plan.
  2. An unprivileged console user cannot change boot sequence and authorized recovery access remains available when necessary.
  3. A test visitor cannot enter unattended after another user badges in, and access logs reliably identify individual entrants.
  4. A new privileged account cannot gain sensitive roles without independent approval and an attributable provisioning record.

Explanation

Correct Answer

C:

A test visitor cannot enter unattended after another user badges in, and access logs reliably identify individual entrants. This directly verifies Implementing a vestibule for data hall entry instead of shared access cards. Required action: Implement approved mantrap or access vestibule controls with anti-tailgating procedures and individual authorization tracking. Why it is a suitable test: Physical access controls must prevent unauthorized person-following as well as authenticate the badge holder.

Incorrect Answers

A:

An approved inspection confirms detection, alarm, suppression and safe human evacuation behavior under a supervised test plan. This verifies the separate Choosing fire suppression appropriate for energized IT racks situation rather than Implementing a vestibule for data hall entry instead of shared access cards. The decisive outcome here is: A test visitor cannot enter unattended after another user badges in, and access logs reliably identify individual entrants.

B:

An unprivileged console user cannot change boot sequence and authorized recovery access remains available when necessary. This verifies the separate Protecting firmware boot settings against unauthorized physical modification situation rather than Implementing a vestibule for data hall entry instead of shared access cards. The decisive outcome here is: A test visitor cannot enter unattended after another user badges in, and access logs reliably identify individual entrants.

D:

A new privileged account cannot gain sensitive roles without independent approval and an attributable provisioning record. This verifies the separate Separating account provisioning from access approval situation rather than Implementing a vestibule for data hall entry instead of shared access cards. The decisive outcome here is: A test visitor cannot enter unattended after another user badges in, and access logs reliably identify individual entrants.

Question 463

A server administrator explains the technical behavior behind this situation: A colocation suite uses a single badge reader and employees regularly hold its door for visitors, bypassing intended controlled entry records. Which technical principle most directly explains the correct approach?

  1. Physical barriers and custody records protect assets before OS or application identity controls apply.
  2. Hardware startup controls operate before OS identity policies and require their own authorization boundary.
  3. Physical access controls must prevent unauthorized person-following as well as authenticate the badge holder.
  4. Segregation of duties reduces single-person control over high-impact account creation and authorization.

Explanation

Correct Answer

C:

Physical access controls must prevent unauthorized person-following as well as authenticate the badge holder. This is the governing technical explanation for Implementing a vestibule for data hall entry instead of shared access cards. Correct configuration: Implement approved mantrap or access vestibule controls with anti-tailgating procedures and individual authorization tracking. Observable outcome: A test visitor cannot enter unattended after another user badges in, and access logs reliably identify individual entrants.

Incorrect Answers

A:

Physical barriers and custody records protect assets before OS or application identity controls apply. That principle describes Restricting removable server equipment through secured cages, not the mechanism that governs Implementing a vestibule for data hall entry instead of shared access cards. The relevant principle is: Physical access controls must prevent unauthorized person-following as well as authenticate the badge holder.

B:

Hardware startup controls operate before OS identity policies and require their own authorization boundary. That principle describes Protecting server UEFI boot order against unauthorized external media, not the mechanism that governs Implementing a vestibule for data hall entry instead of shared access cards. The relevant principle is: Physical access controls must prevent unauthorized person-following as well as authenticate the badge holder.

D:

Segregation of duties reduces single-person control over high-impact account creation and authorization. That principle describes Separating account provisioning from access approval, not the mechanism that governs Implementing a vestibule for data hall entry instead of shared access cards. The relevant principle is: Physical access controls must prevent unauthorized person-following as well as authenticate the badge holder.

Question 464

The server team omits a necessary safeguard. A colocation suite uses a single badge reader and employees regularly hold its door for visitors, bypassing intended controlled entry records. Which resulting operational or security exposure is the most direct?

  1. An unattended person may remove disk media or implant hardware without triggering network security alerts.
  2. Tailgating can expose racks and storage media even when every network firewall is correctly configured.
  3. An abandoned component may remain exploitable even when the host kernel and firewall are fully patched.
  4. A stolen unencrypted backup disk can expose confidential client records even when the source server is hardened.

Explanation

Correct Answer

B:

Tailgating can expose racks and storage media even when every network firewall is correctly configured. This is the central risk in Implementing a vestibule for data hall entry instead of shared access cards. Appropriate safeguard: Implement approved mantrap or access vestibule controls with anti-tailgating procedures and individual authorization tracking. Evidence the safeguard works: A test visitor cannot enter unattended after another user badges in, and access logs reliably identify individual entrants.

Incorrect Answers

A:

An unattended person may remove disk media or implant hardware without triggering network security alerts. This exposure applies to Restricting removable server equipment through secured cages, not the direct consequence of Implementing a vestibule for data hall entry instead of shared access cards. The actual case-specific risk is: Tailgating can expose racks and storage media even when every network firewall is correctly configured.

C:

An abandoned component may remain exploitable even when the host kernel and firewall are fully patched. This exposure applies to Removing outdated application modules from a server image, not the direct consequence of Implementing a vestibule for data hall entry instead of shared access cards. The actual case-specific risk is: Tailgating can expose racks and storage media even when every network firewall is correctly configured.

D:

A stolen unencrypted backup disk can expose confidential client records even when the source server is hardened. This exposure applies to Encrypting data at rest for a removable backup drive, not the direct consequence of Implementing a vestibule for data hall entry instead of shared access cards. The actual case-specific risk is: Tailgating can expose racks and storage media even when every network firewall is correctly configured.

Question 465

The server fault remains unresolved: A colocation suite uses a single badge reader and employees regularly hold its door for visitors, bypassing intended controlled entry records. Which evidence should be examined first to diagnose this particular issue?

  1. Inspect rack lock access logs, visitor passes, camera coverage, drive labels and media custody records.
  2. Inspect workflow approvals, provisioning events, role assignment history and audit ownership.
  3. Inspect UEFI security configuration, boot order, authorized recovery procedures and physical console audit.
  4. Inspect badge events, door sensors, visitor workflow, security camera evidence and incident response process.

Explanation

Correct Answer

D:

Inspect badge events, door sensors, visitor workflow, security camera evidence and incident response process. These checks target the described failure in Implementing a vestibule for data hall entry instead of shared access cards. Appropriate response: Implement approved mantrap or access vestibule controls with anti-tailgating procedures and individual authorization tracking. Success criteria: A test visitor cannot enter unattended after another user badges in, and access logs reliably identify individual entrants.

Incorrect Answers

A:

Inspect rack lock access logs, visitor passes, camera coverage, drive labels and media custody records. Those checks investigate Restricting removable server equipment through secured cages instead of the Implementing a vestibule for data hall entry instead of shared access cards failure. The focused investigation should be: Inspect badge events, door sensors, visitor workflow, security camera evidence and incident response process.

B:

Inspect workflow approvals, provisioning events, role assignment history and audit ownership. Those checks investigate Separating account provisioning from access approval instead of the Implementing a vestibule for data hall entry instead of shared access cards failure. The focused investigation should be: Inspect badge events, door sensors, visitor workflow, security camera evidence and incident response process.

C:

Inspect UEFI security configuration, boot order, authorized recovery procedures and physical console audit. Those checks investigate Protecting firmware boot settings against unauthorized physical modification instead of the Implementing a vestibule for data hall entry instead of shared access cards failure. The focused investigation should be: Inspect badge events, door sensors, visitor workflow, security camera evidence and incident response process.

Question 466

A CompTIA Server+ SK0-005 administrator reviews this production scenario: Facilities plans to use ordinary water sprinklers directly over a sensitive server row without assessing local fire code, equipment constraints or a documented suppression design. Which configuration or design change most directly solves the requirement?

  1. Consult qualified fire-protection staff and deploy a code-compliant detection and suppression system suitable for the facility's electrical and occupancy conditions.
  2. Restore manufacturer-approved relative humidity and grounding conditions through facilities controls and safe maintenance procedures.
  3. Deploy an approved host protection policy with validated application exclusions, alerting and controlled enforcement tests.
  4. Use approved dependency discovery and documented decommission change approval before disconnecting or sanitizing the system.

Explanation

Correct Answer

A:

Consult qualified fire-protection staff and deploy a code-compliant detection and suppression system suitable for the facility's electrical and occupancy conditions. Technical basis: Fire protection requires life-safety compliance and suitable suppression for the specific occupied electrical environment. Acceptance evidence: An approved inspection confirms detection, alarm, suppression and safe human evacuation behavior under a supervised test plan. Deployment boundary: Confirm the server vendor hardware compatibility list, current operating system or hypervisor support, approved permissions, maintenance and backup processes before applying this educational example to production.

Incorrect Answers

B:

Restore manufacturer-approved relative humidity and grounding conditions through facilities controls and safe maintenance procedures. This is a sensible intervention in the separate Diagnosing environmental humidity alarms before swapping hardware scenario. It does not resolve the present Choosing fire suppression appropriate for energized IT racks requirement. For the current problem, use: Consult qualified fire-protection staff and deploy a code-compliant detection and suppression system suitable for the facility's electrical and occupancy conditions.

C:

Deploy an approved host protection policy with validated application exclusions, alerting and controlled enforcement tests. This is a sensible intervention in the separate Configuring host intrusion prevention without disabling application traffic scenario. It does not resolve the present Choosing fire suppression appropriate for energized IT racks requirement. For the current problem, use: Consult qualified fire-protection staff and deploy a code-compliant detection and suppression system suitable for the facility's electrical and occupancy conditions.

D:

Use approved dependency discovery and documented decommission change approval before disconnecting or sanitizing the system. This is a sensible intervention in the separate Verifying server non-use before storage retirement scenario. It does not resolve the present Choosing fire suppression appropriate for energized IT racks requirement. For the current problem, use: Consult qualified fire-protection staff and deploy a code-compliant detection and suppression system suitable for the facility's electrical and occupancy conditions.

Question 467

During a CompTIA Server+ incident recovery verification, the team observes: Facilities plans to use ordinary water sprinklers directly over a sensitive server row without assessing local fire code, equipment constraints or a documented suppression design. Which result is the most convincing evidence of the required outcome?

  1. A safe detection test is blocked and logged while backup and database transactions continue normally.
  2. A test visitor cannot enter unattended after another user badges in, and access logs reliably identify individual entrants.
  3. An approved inspection confirms detection, alarm, suppression and safe human evacuation behavior under a supervised test plan.
  4. A controlled site failure demonstrates the documented commit-consistency and measured data-loss behavior of the selected method.

Explanation

Correct Answer

C:

An approved inspection confirms detection, alarm, suppression and safe human evacuation behavior under a supervised test plan. This directly verifies Choosing fire suppression appropriate for energized IT racks. Required action: Consult qualified fire-protection staff and deploy a code-compliant detection and suppression system suitable for the facility's electrical and occupancy conditions. Why it is a suitable test: Fire protection requires life-safety compliance and suitable suppression for the specific occupied electrical environment.

Incorrect Answers

A:

A safe detection test is blocked and logged while backup and database transactions continue normally. This verifies the separate Configuring host intrusion prevention without disabling application traffic situation rather than Choosing fire suppression appropriate for energized IT racks. The decisive outcome here is: An approved inspection confirms detection, alarm, suppression and safe human evacuation behavior under a supervised test plan.

B:

A test visitor cannot enter unattended after another user badges in, and access logs reliably identify individual entrants. This verifies the separate Implementing a vestibule for data hall entry instead of shared access cards situation rather than Choosing fire suppression appropriate for energized IT racks. The decisive outcome here is: An approved inspection confirms detection, alarm, suppression and safe human evacuation behavior under a supervised test plan.

D:

A controlled site failure demonstrates the documented commit-consistency and measured data-loss behavior of the selected method. This verifies the separate Distinguishing synchronous replication latency from asynchronous loss exposure situation rather than Choosing fire suppression appropriate for energized IT racks. The decisive outcome here is: An approved inspection confirms detection, alarm, suppression and safe human evacuation behavior under a supervised test plan.

Question 468

A server administrator explains the technical behavior behind this situation: Facilities plans to use ordinary water sprinklers directly over a sensitive server row without assessing local fire code, equipment constraints or a documented suppression design. Which technical principle most directly explains the correct approach?

  1. Temperature, humidity and electrical grounding are distinct environmental risk factors affecting hardware reliability.
  2. Electronics recycling combines environmental responsibilities and secure handling of residual information assets.
  3. Fire protection requires life-safety compliance and suitable suppression for the specific occupied electrical environment.
  4. File backups and system-state backups protect different components required for complete service recovery.

Explanation

Correct Answer

C:

Fire protection requires life-safety compliance and suitable suppression for the specific occupied electrical environment. This is the governing technical explanation for Choosing fire suppression appropriate for energized IT racks. Correct configuration: Consult qualified fire-protection staff and deploy a code-compliant detection and suppression system suitable for the facility's electrical and occupancy conditions. Observable outcome: An approved inspection confirms detection, alarm, suppression and safe human evacuation behavior under a supervised test plan.

Incorrect Answers

A:

Temperature, humidity and electrical grounding are distinct environmental risk factors affecting hardware reliability. That principle describes Diagnosing environmental humidity alarms before swapping hardware, not the mechanism that governs Choosing fire suppression appropriate for energized IT racks. The relevant principle is: Fire protection requires life-safety compliance and suitable suppression for the specific occupied electrical environment.

B:

Electronics recycling combines environmental responsibilities and secure handling of residual information assets. That principle describes Choosing certified electronics recycling rather than informal resale, not the mechanism that governs Choosing fire suppression appropriate for energized IT racks. The relevant principle is: Fire protection requires life-safety compliance and suitable suppression for the specific occupied electrical environment.

D:

File backups and system-state backups protect different components required for complete service recovery. That principle describes Validating a system-state restore separately from ordinary file recovery, not the mechanism that governs Choosing fire suppression appropriate for energized IT racks. The relevant principle is: Fire protection requires life-safety compliance and suitable suppression for the specific occupied electrical environment.

Question 469

The server team omits a necessary safeguard. Facilities plans to use ordinary water sprinklers directly over a sensitive server row without assessing local fire code, equipment constraints or a documented suppression design. Which resulting operational or security exposure is the most direct?

  1. Low humidity and poor ESD controls can cause repeated component damage despite successful individual repairs.
  2. Stale roles can let a single compromised employee account control unrelated infrastructure segments.
  3. An abandoned component may remain exploitable even when the host kernel and firewall are fully patched.
  4. An unsuitable or unapproved system can harm occupants, damage equipment or fail to control a fire.

Explanation

Correct Answer

D:

An unsuitable or unapproved system can harm occupants, damage equipment or fail to control a fire. This is the central risk in Choosing fire suppression appropriate for energized IT racks. Appropriate safeguard: Consult qualified fire-protection staff and deploy a code-compliant detection and suppression system suitable for the facility's electrical and occupancy conditions. Evidence the safeguard works: An approved inspection confirms detection, alarm, suppression and safe human evacuation behavior under a supervised test plan.

Incorrect Answers

A:

Low humidity and poor ESD controls can cause repeated component damage despite successful individual repairs. This exposure applies to Diagnosing environmental humidity alarms before swapping hardware, not the direct consequence of Choosing fire suppression appropriate for energized IT racks. The actual case-specific risk is: An unsuitable or unapproved system can harm occupants, damage equipment or fail to control a fire.

B:

Stale roles can let a single compromised employee account control unrelated infrastructure segments. This exposure applies to Investigating privilege drift after employee team transfer, not the direct consequence of Choosing fire suppression appropriate for energized IT racks. The actual case-specific risk is: An unsuitable or unapproved system can harm occupants, damage equipment or fail to control a fire.

C:

An abandoned component may remain exploitable even when the host kernel and firewall are fully patched. This exposure applies to Removing outdated application modules from a server image, not the direct consequence of Choosing fire suppression appropriate for energized IT racks. The actual case-specific risk is: An unsuitable or unapproved system can harm occupants, damage equipment or fail to control a fire.

Question 470

The server fault remains unresolved: Facilities plans to use ordinary water sprinklers directly over a sensitive server row without assessing local fire code, equipment constraints or a documented suppression design. Which evidence should be examined first to diagnose this particular issue?

  1. Inspect code approvals, suppression design, detection sensors, safety procedures and maintenance certificates.
  2. Inspect badge events, door sensors, visitor workflow, security camera evidence and incident response process.
  3. Inspect media type, manufacturer sanitization support, destruction certificate and asset disposal trail.
  4. Inspect UEFI security configuration, boot order, authorized recovery procedures and physical console audit.

Explanation

Correct Answer

A:

Inspect code approvals, suppression design, detection sensors, safety procedures and maintenance certificates. These checks target the described failure in Choosing fire suppression appropriate for energized IT racks. Appropriate response: Consult qualified fire-protection staff and deploy a code-compliant detection and suppression system suitable for the facility's electrical and occupancy conditions. Success criteria: An approved inspection confirms detection, alarm, suppression and safe human evacuation behavior under a supervised test plan.

Incorrect Answers

B:

Inspect badge events, door sensors, visitor workflow, security camera evidence and incident response process. Those checks investigate Implementing a vestibule for data hall entry instead of shared access cards instead of the Choosing fire suppression appropriate for energized IT racks failure. The focused investigation should be: Inspect code approvals, suppression design, detection sensors, safety procedures and maintenance certificates.

C:

Inspect media type, manufacturer sanitization support, destruction certificate and asset disposal trail. Those checks investigate Selecting verifiable SSD sanitization rather than magnetic degaussing instead of the Choosing fire suppression appropriate for energized IT racks failure. The focused investigation should be: Inspect code approvals, suppression design, detection sensors, safety procedures and maintenance certificates.

D:

Inspect UEFI security configuration, boot order, authorized recovery procedures and physical console audit. Those checks investigate Protecting firmware boot settings against unauthorized physical modification instead of the Choosing fire suppression appropriate for energized IT racks failure. The focused investigation should be: Inspect code approvals, suppression design, detection sensors, safety procedures and maintenance certificates.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Purchase Individually

  • Premium File

    617 Questions & Answers
    Last Update: Nov 9, 2026

    $76.99
    $69.99
  • Training Course

    139 Lectures

    $43.99
    $39.99
  • Study Guide

    533 Pages

    $43.99
    $39.99

SPECIAL OFFER: GET 10% OFF
This is ONE TIME OFFER

You save
10%

Enter Your Email Address to Receive Your 10% Off Discount Code

SPECIAL OFFER: GET 10% OFF

You save
10%

Use Discount Code:

A confirmation link was sent to your e-mail.

Please check your mailbox for a message from support@examlabs.com and follow the directions.

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your email address below to get started with our interactive software demo of your free trial.

  • Realistic exam simulation and exam editor with preview functions
  • Whole exam in a single file with several different question types
  • Customizable exam-taking mode & detailed score reports