Pass CompTIA Server+ SK0-005 Exam in First Attempt Easily
Real CompTIA Server+ SK0-005 Exam Questions, Accurate & Verified Answers As Experienced in the Actual Test!

Verified by experts
3 products

You save $69.98

SK0-005 Premium Bundle

  • Premium File 617 Questions & Answers
  • Last Update: Nov 9, 2026
  • Training Course 139 Lectures
  • Study Guide 533 Pages
$79.99 $149.97

Purchase Individually

  • Premium File

    617 Questions & Answers
    Last Update: Nov 9, 2026

    $76.99
    $69.99
  • Training Course

    139 Lectures

    $43.99
    $39.99
  • Study Guide

    533 Pages

    $43.99
    $39.99

CompTIA Server+ Certification Exam SK0-005 Practice Test 59

Question 580

The server fault remains unresolved: A technician plans to degauss failed SSDs containing sensitive client data because the same method was historically used for magnetic hard disks. Which evidence should be examined first to diagnose this particular issue?

  1. Inspect lease schedule, drive serial inventory, sanitization attestations and receipt confirmation.
  2. Inspect code approvals, suppression design, detection sensors, safety procedures and maintenance certificates.
  3. Inspect management VLAN, controller certificates, role grants, web access logs and negative authorization tests.
  4. Inspect media type, manufacturer sanitization support, destruction certificate and asset disposal trail.

Explanation

Correct Answer

D:

Inspect media type, manufacturer sanitization support, destruction certificate and asset disposal trail. These checks target the described failure in Selecting verifiable SSD sanitization rather than magnetic degaussing. Appropriate response: Use supported cryptographic erase, verified secure sanitization or approved physical destruction appropriate to SSD media and policy. Success criteria: Custody and sanitization evidence shows the SSD cannot expose recoverable protected data through the supported verification process.

Incorrect Answers

A:

Inspect lease schedule, drive serial inventory, sanitization attestations and receipt confirmation. Those checks investigate Documenting leased-server returns without surrendering retained drives instead of the Selecting verifiable SSD sanitization rather than magnetic degaussing failure. The focused investigation should be: Inspect media type, manufacturer sanitization support, destruction certificate and asset disposal trail.

B:

Inspect code approvals, suppression design, detection sensors, safety procedures and maintenance certificates. Those checks investigate Choosing fire suppression appropriate for energized IT racks instead of the Selecting verifiable SSD sanitization rather than magnetic degaussing failure. The focused investigation should be: Inspect media type, manufacturer sanitization support, destruction certificate and asset disposal trail.

C:

Inspect management VLAN, controller certificates, role grants, web access logs and negative authorization tests. Those checks investigate Restricting administrative web UI access for storage controllers instead of the Selecting verifiable SSD sanitization rather than magnetic degaussing failure. The focused investigation should be: Inspect media type, manufacturer sanitization support, destruction certificate and asset disposal trail.

Question 581

A CompTIA Server+ SK0-005 administrator reviews this production scenario: A company sends decommissioned leased servers back to a hardware vendor without checking contractual data-retention rights or recording disk serials. Which configuration or design change most directly solves the requirement?

  1. Use supported cryptographic erase, verified secure sanitization or approved physical destruction appropriate to SSD media and policy.
  2. Correlate authorized identity, file access and outbound transfer telemetry with DLP or SIEM rules under privacy and retention policy.
  3. Follow signed lease return and data-retention terms; remove, sanitize or securely transfer storage only under approved procedures.
  4. Remove unnecessary modules and update required components under application-supported change and rollback procedures.

Explanation

Correct Answer

C:

Follow signed lease return and data-retention terms; remove, sanitize or securely transfer storage only under approved procedures. Technical basis: Leased equipment ownership and media confidentiality obligations can differ during asset retirement. Acceptance evidence: Returned hardware and retained or destroyed drives are reconciled to an approved serial-level custody list. Deployment boundary: Confirm the server vendor hardware compatibility list, current operating system or hypervisor support, approved permissions, maintenance and backup processes before applying this educational example to production.

Incorrect Answers

A:

Use supported cryptographic erase, verified secure sanitization or approved physical destruction appropriate to SSD media and policy. This is a sensible intervention in the separate Selecting verifiable SSD sanitization rather than magnetic degaussing scenario. It does not resolve the present Documenting leased-server returns without surrendering retained drives requirement. For the current problem, use: Follow signed lease return and data-retention terms; remove, sanitize or securely transfer storage only under approved procedures.

B:

Correlate authorized identity, file access and outbound transfer telemetry with DLP or SIEM rules under privacy and retention policy. This is a sensible intervention in the separate Detecting an insider bulk data export with correlated logs scenario. It does not resolve the present Documenting leased-server returns without surrendering retained drives requirement. For the current problem, use: Follow signed lease return and data-retention terms; remove, sanitize or securely transfer storage only under approved procedures.

D:

Remove unnecessary modules and update required components under application-supported change and rollback procedures. This is a sensible intervention in the separate Removing outdated application modules from a server image scenario. It does not resolve the present Documenting leased-server returns without surrendering retained drives requirement. For the current problem, use: Follow signed lease return and data-retention terms; remove, sanitize or securely transfer storage only under approved procedures.

Question 582

During a CompTIA Server+ incident recovery verification, the team observes: A company sends decommissioned leased servers back to a hardware vendor without checking contractual data-retention rights or recording disk serials. Which result is the most convincing evidence of the required outcome?

  1. Custody and sanitization evidence shows the SSD cannot expose recoverable protected data through the supported verification process.
  2. Environmental sensors return to approved range and subsequent controlled hardware maintenance shows no abnormal ESD events.
  3. Inventory lists recoverable weekly points and an isolated sample restore uses a retained earlier tape.
  4. Returned hardware and retained or destroyed drives are reconciled to an approved serial-level custody list.

Explanation

Correct Answer

D:

Returned hardware and retained or destroyed drives are reconciled to an approved serial-level custody list. This directly verifies Documenting leased-server returns without surrendering retained drives. Required action: Follow signed lease return and data-retention terms; remove, sanitize or securely transfer storage only under approved procedures. Why it is a suitable test: Leased equipment ownership and media confidentiality obligations can differ during asset retirement.

Incorrect Answers

A:

Custody and sanitization evidence shows the SSD cannot expose recoverable protected data through the supported verification process. This verifies the separate Selecting verifiable SSD sanitization rather than magnetic degaussing situation rather than Documenting leased-server returns without surrendering retained drives. The decisive outcome here is: Returned hardware and retained or destroyed drives are reconciled to an approved serial-level custody list.

B:

Environmental sensors return to approved range and subsequent controlled hardware maintenance shows no abnormal ESD events. This verifies the separate Diagnosing environmental humidity alarms before swapping hardware situation rather than Documenting leased-server returns without surrendering retained drives. The decisive outcome here is: Returned hardware and retained or destroyed drives are reconciled to an approved serial-level custody list.

C:

Inventory lists recoverable weekly points and an isolated sample restore uses a retained earlier tape. This verifies the separate Rotating backups away from a single removable tape situation rather than Documenting leased-server returns without surrendering retained drives. The decisive outcome here is: Returned hardware and retained or destroyed drives are reconciled to an approved serial-level custody list.

Question 583

A server administrator explains the technical behavior behind this situation: A company sends decommissioned leased servers back to a hardware vendor without checking contractual data-retention rights or recording disk serials. Which technical principle most directly explains the correct approach?

  1. Encryption protects confidentiality but does not set lawful retention, ownership or deletion requirements.
  2. Legal retention exceptions must preserve evidence integrity without abandoning confidentiality or access accountability.
  3. Decommissioning must establish a server is unused before irreversible media and resource removal.
  4. Leased equipment ownership and media confidentiality obligations can differ during asset retirement.

Explanation

Correct Answer

D:

Leased equipment ownership and media confidentiality obligations can differ during asset retirement. This is the governing technical explanation for Documenting leased-server returns without surrendering retained drives. Correct configuration: Follow signed lease return and data-retention terms; remove, sanitize or securely transfer storage only under approved procedures. Observable outcome: Returned hardware and retained or destroyed drives are reconciled to an approved serial-level custody list.

Incorrect Answers

A:

Encryption protects confidentiality but does not set lawful retention, ownership or deletion requirements. That principle describes Applying retention policy to encrypted archive storage, not the mechanism that governs Documenting leased-server returns without surrendering retained drives. The relevant principle is: Leased equipment ownership and media confidentiality obligations can differ during asset retirement.

B:

Legal retention exceptions must preserve evidence integrity without abandoning confidentiality or access accountability. That principle describes Handling a legal hold without arbitrary deletion of security evidence, not the mechanism that governs Documenting leased-server returns without surrendering retained drives. The relevant principle is: Leased equipment ownership and media confidentiality obligations can differ during asset retirement.

C:

Decommissioning must establish a server is unused before irreversible media and resource removal. That principle describes Verifying server non-use before storage retirement, not the mechanism that governs Documenting leased-server returns without surrendering retained drives. The relevant principle is: Leased equipment ownership and media confidentiality obligations can differ during asset retirement.

Question 584

The server team omits a necessary safeguard. A company sends decommissioned leased servers back to a hardware vendor without checking contractual data-retention rights or recording disk serials. Which resulting operational or security exposure is the most direct?

  1. Uncontrolled resale can expose data and violate hardware disposal requirements despite removing servers from inventory.
  2. Untracked storage drives may leave the organization with sensitive records and no proof of disposition.
  3. One compromised administrator could decrypt or permanently destroy the only accessible sensitive archive.
  4. An untuned security agent may cause outages or be disabled entirely after false positives.

Explanation

Correct Answer

B:

Untracked storage drives may leave the organization with sensitive records and no proof of disposition. This is the central risk in Documenting leased-server returns without surrendering retained drives. Appropriate safeguard: Follow signed lease return and data-retention terms; remove, sanitize or securely transfer storage only under approved procedures. Evidence the safeguard works: Returned hardware and retained or destroyed drives are reconciled to an approved serial-level custody list.

Incorrect Answers

A:

Uncontrolled resale can expose data and violate hardware disposal requirements despite removing servers from inventory. This exposure applies to Choosing certified electronics recycling rather than informal resale, not the direct consequence of Documenting leased-server returns without surrendering retained drives. The actual case-specific risk is: Untracked storage drives may leave the organization with sensitive records and no proof of disposition.

C:

One compromised administrator could decrypt or permanently destroy the only accessible sensitive archive. This exposure applies to Applying two-person integrity to high-value encryption keys, not the direct consequence of Documenting leased-server returns without surrendering retained drives. The actual case-specific risk is: Untracked storage drives may leave the organization with sensitive records and no proof of disposition.

D:

An untuned security agent may cause outages or be disabled entirely after false positives. This exposure applies to Configuring host intrusion prevention without disabling application traffic, not the direct consequence of Documenting leased-server returns without surrendering retained drives. The actual case-specific risk is: Untracked storage drives may leave the organization with sensitive records and no proof of disposition.

Question 585

The server fault remains unresolved: A company sends decommissioned leased servers back to a hardware vendor without checking contractual data-retention rights or recording disk serials. Which evidence should be examined first to diagnose this particular issue?

  1. Inspect lease schedule, drive serial inventory, sanitization attestations and receipt confirmation.
  2. Inspect media type, manufacturer sanitization support, destruction certificate and asset disposal trail.
  3. Inspect retention schedule, snapshot inventories, hold tags, deletion logs and approved exceptions.
  4. Inspect release advisory, staging outcomes, patch inventory, application tests and rollback readiness.

Explanation

Correct Answer

A:

Inspect lease schedule, drive serial inventory, sanitization attestations and receipt confirmation. These checks target the described failure in Documenting leased-server returns without surrendering retained drives. Appropriate response: Follow signed lease return and data-retention terms; remove, sanitize or securely transfer storage only under approved procedures. Success criteria: Returned hardware and retained or destroyed drives are reconciled to an approved serial-level custody list.

Incorrect Answers

B:

Inspect media type, manufacturer sanitization support, destruction certificate and asset disposal trail. Those checks investigate Selecting verifiable SSD sanitization rather than magnetic degaussing instead of the Documenting leased-server returns without surrendering retained drives failure. The focused investigation should be: Inspect lease schedule, drive serial inventory, sanitization attestations and receipt confirmation.

C:

Inspect retention schedule, snapshot inventories, hold tags, deletion logs and approved exceptions. Those checks investigate Applying retention policy to encrypted archive storage instead of the Documenting leased-server returns without surrendering retained drives failure. The focused investigation should be: Inspect lease schedule, drive serial inventory, sanitization attestations and receipt confirmation.

D:

Inspect release advisory, staging outcomes, patch inventory, application tests and rollback readiness. Those checks investigate Staging security patch rollout to avoid unplanned fleet outage instead of the Documenting leased-server returns without surrendering retained drives failure. The focused investigation should be: Inspect lease schedule, drive serial inventory, sanitization attestations and receipt confirmation.

Question 586

A CompTIA Server+ SK0-005 administrator reviews this production scenario: A datacenter removes an obsolete server but leaves live unlabeled power cords and fiber links in the rack, creating hazards for new hardware service work. Which configuration or design change most directly solves the requirement?

  1. Remove unnecessary modules and update required components under application-supported change and rollback procedures.
  2. Follow signed lease return and data-retention terms; remove, sanitize or securely transfer storage only under approved procedures.
  3. De-energize and remove obsolete cables under approved change control, updating PDU and network port documentation.
  4. Schedule an approved full-plus-incremental or other appropriate backup strategy that meets the documented recovery point requirement.

Explanation

Correct Answer

C:

De-energize and remove obsolete cables under approved change control, updating PDU and network port documentation. Technical basis: Cable remediation is part of complete server decommissioning and not merely disposal of compute hardware. Acceptance evidence: The vacated rack units have no unidentified live connections and cable maps match actual remaining endpoints. Deployment boundary: Confirm the server vendor hardware compatibility list, current operating system or hypervisor support, approved permissions, maintenance and backup processes before applying this educational example to production.

Incorrect Answers

A:

Remove unnecessary modules and update required components under application-supported change and rollback procedures. This is a sensible intervention in the separate Removing outdated application modules from a server image scenario. It does not resolve the present Cleaning power and fiber cabling after rack asset removal requirement. For the current problem, use: De-energize and remove obsolete cables under approved change control, updating PDU and network port documentation.

B:

Follow signed lease return and data-retention terms; remove, sanitize or securely transfer storage only under approved procedures. This is a sensible intervention in the separate Documenting leased-server returns without surrendering retained drives scenario. It does not resolve the present Cleaning power and fiber cabling after rack asset removal requirement. For the current problem, use: De-energize and remove obsolete cables under approved change control, updating PDU and network port documentation.

D:

Schedule an approved full-plus-incremental or other appropriate backup strategy that meets the documented recovery point requirement. This is a sensible intervention in the separate Selecting incremental backups for frequent changes under an RPO scenario. It does not resolve the present Cleaning power and fiber cabling after rack asset removal requirement. For the current problem, use: De-energize and remove obsolete cables under approved change control, updating PDU and network port documentation.

Question 587

During a CompTIA Server+ incident recovery verification, the team observes: A datacenter removes an obsolete server but leaves live unlabeled power cords and fiber links in the rack, creating hazards for new hardware service work. Which result is the most convincing evidence of the required outcome?

  1. Each retired serial number maps to a vetted disposal receipt and the storage media has separate confidentiality evidence.
  2. Network capture confirms no readable application records traverse the path and legitimate endpoints complete authenticated synchronization.
  3. Effective permissions match the current job responsibilities and no former network admin capability remains.
  4. The vacated rack units have no unidentified live connections and cable maps match actual remaining endpoints.

Explanation

Correct Answer

D:

The vacated rack units have no unidentified live connections and cable maps match actual remaining endpoints. This directly verifies Cleaning power and fiber cabling after rack asset removal. Required action: De-energize and remove obsolete cables under approved change control, updating PDU and network port documentation. Why it is a suitable test: Cable remediation is part of complete server decommissioning and not merely disposal of compute hardware.

Incorrect Answers

A:

Each retired serial number maps to a vetted disposal receipt and the storage media has separate confidentiality evidence. This verifies the separate Choosing certified electronics recycling rather than informal resale situation rather than Cleaning power and fiber cabling after rack asset removal. The decisive outcome here is: The vacated rack units have no unidentified live connections and cable maps match actual remaining endpoints.

B:

Network capture confirms no readable application records traverse the path and legitimate endpoints complete authenticated synchronization. This verifies the separate Protecting replication data in transit across an untrusted path situation rather than Cleaning power and fiber cabling after rack asset removal. The decisive outcome here is: The vacated rack units have no unidentified live connections and cable maps match actual remaining endpoints.

C:

Effective permissions match the current job responsibilities and no former network admin capability remains. This verifies the separate Investigating privilege drift after employee team transfer situation rather than Cleaning power and fiber cabling after rack asset removal. The decisive outcome here is: The vacated rack units have no unidentified live connections and cable maps match actual remaining endpoints.

Question 588

A server administrator explains the technical behavior behind this situation: A datacenter removes an obsolete server but leaves live unlabeled power cords and fiber links in the rack, creating hazards for new hardware service work. Which technical principle most directly explains the correct approach?

  1. Decommissioning must establish a server is unused before irreversible media and resource removal.
  2. File backups and system-state backups protect different components required for complete service recovery.
  3. Patch management combines vulnerability remediation with compatibility testing, scheduling and restoration capability.
  4. Cable remediation is part of complete server decommissioning and not merely disposal of compute hardware.

Explanation

Correct Answer

D:

Cable remediation is part of complete server decommissioning and not merely disposal of compute hardware. This is the governing technical explanation for Cleaning power and fiber cabling after rack asset removal. Correct configuration: De-energize and remove obsolete cables under approved change control, updating PDU and network port documentation. Observable outcome: The vacated rack units have no unidentified live connections and cable maps match actual remaining endpoints.

Incorrect Answers

A:

Decommissioning must establish a server is unused before irreversible media and resource removal. That principle describes Verifying server non-use before storage retirement, not the mechanism that governs Cleaning power and fiber cabling after rack asset removal. The relevant principle is: Cable remediation is part of complete server decommissioning and not merely disposal of compute hardware.

B:

File backups and system-state backups protect different components required for complete service recovery. That principle describes Validating a system-state restore separately from ordinary file recovery, not the mechanism that governs Cleaning power and fiber cabling after rack asset removal. The relevant principle is: Cable remediation is part of complete server decommissioning and not merely disposal of compute hardware.

C:

Patch management combines vulnerability remediation with compatibility testing, scheduling and restoration capability. That principle describes Staging security patch rollout to avoid unplanned fleet outage, not the mechanism that governs Cleaning power and fiber cabling after rack asset removal. The relevant principle is: Cable remediation is part of complete server decommissioning and not merely disposal of compute hardware.

Question 589

The server team omits a necessary safeguard. A datacenter removes an obsolete server but leaves live unlabeled power cords and fiber links in the rack, creating hazards for new hardware service work. Which resulting operational or security exposure is the most direct?

  1. Premature destruction can remove a hidden business dependency and create a longer outage than a controlled migration.
  2. Unused energized cords and mislabelled fibers can cause safety events or accidental network outages later.
  3. An untuned security agent may cause outages or be disabled entirely after false positives.
  4. Overprivileged backup roles create opportunities for accidental data deletion or domain compromise.

Explanation

Correct Answer

B:

Unused energized cords and mislabelled fibers can cause safety events or accidental network outages later. This is the central risk in Cleaning power and fiber cabling after rack asset removal. Appropriate safeguard: De-energize and remove obsolete cables under approved change control, updating PDU and network port documentation. Evidence the safeguard works: The vacated rack units have no unidentified live connections and cable maps match actual remaining endpoints.

Incorrect Answers

A:

Premature destruction can remove a hidden business dependency and create a longer outage than a controlled migration. This exposure applies to Verifying server non-use before storage retirement, not the direct consequence of Cleaning power and fiber cabling after rack asset removal. The actual case-specific risk is: Unused energized cords and mislabelled fibers can cause safety events or accidental network outages later.

C:

An untuned security agent may cause outages or be disabled entirely after false positives. This exposure applies to Configuring host intrusion prevention without disabling application traffic, not the direct consequence of Cleaning power and fiber cabling after rack asset removal. The actual case-specific risk is: Unused energized cords and mislabelled fibers can cause safety events or accidental network outages later.

D:

Overprivileged backup roles create opportunities for accidental data deletion or domain compromise. This exposure applies to Applying least-privilege RBAC to backup operators, not the direct consequence of Cleaning power and fiber cabling after rack asset removal. The actual case-specific risk is: Unused energized cords and mislabelled fibers can cause safety events or accidental network outages later.

Question 590

The server fault remains unresolved: A datacenter removes an obsolete server but leaves live unlabeled power cords and fiber links in the rack, creating hazards for new hardware service work. Which evidence should be examined first to diagnose this particular issue?

  1. Inspect PDU breakers, cable identifiers, switch ports, rack diagrams and removal signoff.
  2. Inspect CMDB links, DNS references, traffic logs, application owners and retirement approvals.
  3. Inspect package inventories, application plugins, listening ports, dependency manifests and staged regression tests.
  4. Inspect EDR events, affected shares, identity use, network connections and backup-integrity reports.

Explanation

Correct Answer

A:

Inspect PDU breakers, cable identifiers, switch ports, rack diagrams and removal signoff. These checks target the described failure in Cleaning power and fiber cabling after rack asset removal. Appropriate response: De-energize and remove obsolete cables under approved change control, updating PDU and network port documentation. Success criteria: The vacated rack units have no unidentified live connections and cable maps match actual remaining endpoints.

Incorrect Answers

B:

Inspect CMDB links, DNS references, traffic logs, application owners and retirement approvals. Those checks investigate Verifying server non-use before storage retirement instead of the Cleaning power and fiber cabling after rack asset removal failure. The focused investigation should be: Inspect PDU breakers, cable identifiers, switch ports, rack diagrams and removal signoff.

C:

Inspect package inventories, application plugins, listening ports, dependency manifests and staged regression tests. Those checks investigate Removing outdated application modules from a server image instead of the Cleaning power and fiber cabling after rack asset removal failure. The focused investigation should be: Inspect PDU breakers, cable identifiers, switch ports, rack diagrams and removal signoff.

D:

Inspect EDR events, affected shares, identity use, network connections and backup-integrity reports. Those checks investigate Separating ransomware containment from immediate disk reimaging instead of the Cleaning power and fiber cabling after rack asset removal failure. The focused investigation should be: Inspect PDU breakers, cable identifiers, switch ports, rack diagrams and removal signoff.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Purchase Individually

  • Premium File

    617 Questions & Answers
    Last Update: Nov 9, 2026

    $76.99
    $69.99
  • Training Course

    139 Lectures

    $43.99
    $39.99
  • Study Guide

    533 Pages

    $43.99
    $39.99

SPECIAL OFFER: GET 10% OFF
This is ONE TIME OFFER

You save
10%

Enter Your Email Address to Receive Your 10% Off Discount Code

SPECIAL OFFER: GET 10% OFF

You save
10%

Use Discount Code:

A confirmation link was sent to your e-mail.

Please check your mailbox for a message from support@examlabs.com and follow the directions.

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your email address below to get started with our interactive software demo of your free trial.

  • Realistic exam simulation and exam editor with preview functions
  • Whole exam in a single file with several different question types
  • Customizable exam-taking mode & detailed score reports