CompTIA Server+ Certification Exam SK0-005 Practice Test 6

Question 50

The server fault remains unresolved: An office buys newer processors and dense DIMMs for a legacy server board without checking the processor stepping, BIOS support, memory speed or per-channel population rules. Which evidence should be examined first to diagnose this particular issue?

  1. Inspect motherboard DIMM chart, slot LEDs, BIOS memory status and postrepair diagnostics.
  2. Compare chassis part number, rail compatibility chart, cabinet depth, load rating and post-install service clearance.
  3. Inspect RAID health, backup retention, off-array copy location, restore-test evidence and recovery objectives.
  4. Inspect motherboard revision, supported CPU stepping, BIOS version, DIMM part numbers, population chart and burn-in logs.

Explanation

Correct Answer

D:

Inspect motherboard revision, supported CPU stepping, BIOS version, DIMM part numbers, population chart and burn-in logs. These checks target the described failure in Validating CPU and memory platform compatibility before refresh. Appropriate response: Select HCL-supported CPU and DIMM combinations with required BIOS revision and documented channel population order before changing production hardware. Success criteria: Firmware inventories the expected processors and usable memory, and diagnostics pass without corrected-ECC storms or downclock surprises.

Incorrect Answers

A:

Inspect motherboard DIMM chart, slot LEDs, BIOS memory status and postrepair diagnostics. Those checks investigate Choosing DIMM slot placement for replacement memory module instead of the Validating CPU and memory platform compatibility before refresh failure. The focused investigation should be: Inspect motherboard revision, supported CPU stepping, BIOS version, DIMM part numbers, population chart and burn-in logs.

B:

Compare chassis part number, rail compatibility chart, cabinet depth, load rating and post-install service clearance. Those checks investigate Choosing a supported rail kit for a deep server chassis instead of the Validating CPU and memory platform compatibility before refresh failure. The focused investigation should be: Inspect motherboard revision, supported CPU stepping, BIOS version, DIMM part numbers, population chart and burn-in logs.

C:

Inspect RAID health, backup retention, off-array copy location, restore-test evidence and recovery objectives. Those checks investigate Distinguishing RAID 6 redundancy from two independent backups instead of the Validating CPU and memory platform compatibility before refresh failure. The focused investigation should be: Inspect motherboard revision, supported CPU stepping, BIOS version, DIMM part numbers, population chart and burn-in logs.

Question 51

A CompTIA Server+ SK0-005 administrator reviews this production scenario: A technician opens a powered-down rack server in a carpeted work area, removes a PCIe riser without a grounding procedure and places it on conductive packaging. Which configuration or design change most directly solves the requirement?

  1. Follow approved service isolation, antistatic wrist-strap, ESD mat and component-handling procedures before replacing the card.
  2. Obtain the chassis-compatible adjustable rail kit and verify cabinet depth, load rating and attachment points before installing the appliance.
  3. Follow the approved firmware compatibility matrix and staged maintenance process, updating components in the required order with rollback evidence.
  4. Choose enterprise SSD endurance matched to measured daily writes, track spare capacity and plan replacements before wear-out thresholds.

Explanation

Correct Answer

A:

Follow approved service isolation, antistatic wrist-strap, ESD mat and component-handling procedures before replacing the card. Technical basis: Electrostatic discharge can damage small semiconductor features even without an immediately observable spark. Acceptance evidence: Postreplacement hardware diagnostics show the adapter enumerates correctly with no new intermittent errors after a controlled startup. Deployment boundary: Confirm the server vendor hardware compatibility list, current operating system or hypervisor support, approved permissions, maintenance and backup processes before applying this educational example to production.

Incorrect Answers

B:

Obtain the chassis-compatible adjustable rail kit and verify cabinet depth, load rating and attachment points before installing the appliance. This is a sensible intervention in the separate Choosing a supported rail kit for a deep server chassis scenario. It does not resolve the present Preventing static damage while replacing a riser card requirement. For the current problem, use: Follow approved service isolation, antistatic wrist-strap, ESD mat and component-handling procedures before replacing the card.

C:

Follow the approved firmware compatibility matrix and staged maintenance process, updating components in the required order with rollback evidence. This is a sensible intervention in the separate Installing server firmware without skipping compatibility sequencing scenario. It does not resolve the present Preventing static damage while replacing a riser card requirement. For the current problem, use: Follow approved service isolation, antistatic wrist-strap, ESD mat and component-handling procedures before replacing the card.

D:

Choose enterprise SSD endurance matched to measured daily writes, track spare capacity and plan replacements before wear-out thresholds. This is a sensible intervention in the separate Managing write-intensive SSD wear rather than capacity only scenario. It does not resolve the present Preventing static damage while replacing a riser card requirement. For the current problem, use: Follow approved service isolation, antistatic wrist-strap, ESD mat and component-handling procedures before replacing the card.

Question 52

During a CompTIA Server+ incident recovery verification, the team observes: A technician opens a powered-down rack server in a carpeted work area, removes a PCIe riser without a grounding procedure and places it on conductive packaging. Which result is the most convincing evidence of the required outcome?

  1. Firmware inventories the expected processors and usable memory, and diagnostics pass without corrected-ECC storms or downclock surprises.
  2. The correct replacement disk rejoins the array and rebuild completes with no unexpected second member removal.
  3. Postreplacement hardware diagnostics show the adapter enumerates correctly with no new intermittent errors after a controlled startup.
  4. The replacement fan registers normal RPM and inlet temperatures remain within limits after a sustained workload test.

Explanation

Correct Answer

C:

Postreplacement hardware diagnostics show the adapter enumerates correctly with no new intermittent errors after a controlled startup. This directly verifies Preventing static damage while replacing a riser card. Required action: Follow approved service isolation, antistatic wrist-strap, ESD mat and component-handling procedures before replacing the card. Why it is a suitable test: Electrostatic discharge can damage small semiconductor features even without an immediately observable spark.

Incorrect Answers

A:

Firmware inventories the expected processors and usable memory, and diagnostics pass without corrected-ECC storms or downclock surprises. This verifies the separate Validating CPU and memory platform compatibility before refresh situation rather than Preventing static damage while replacing a riser card. The decisive outcome here is: Postreplacement hardware diagnostics show the adapter enumerates correctly with no new intermittent errors after a controlled startup.

B:

The correct replacement disk rejoins the array and rebuild completes with no unexpected second member removal. This verifies the separate Repairing a degraded RAID 5 without pulling the wrong drive situation rather than Preventing static damage while replacing a riser card. The decisive outcome here is: Postreplacement hardware diagnostics show the adapter enumerates correctly with no new intermittent errors after a controlled startup.

D:

The replacement fan registers normal RPM and inlet temperatures remain within limits after a sustained workload test. This verifies the separate Choosing a supported hot-swap fan repair under load situation rather than Preventing static damage while replacing a riser card. The decisive outcome here is: Postreplacement hardware diagnostics show the adapter enumerates correctly with no new intermittent errors after a controlled startup.

Question 53

A server administrator explains the technical behavior behind this situation: A technician opens a powered-down rack server in a carpeted work area, removes a PCIe riser without a grounding procedure and places it on conductive packaging. Which technical principle most directly explains the correct approach?

  1. Rack airflow orientation, containment and cable obstruction control where cold air reaches equipment rather than just room cooling setpoints.
  2. RAID parity provides physical availability, whereas backup restores data after logical damage or destructive events.
  3. Electrostatic discharge can damage small semiconductor features even without an immediately observable spark.
  4. BMC virtual media can emulate removable boot devices independently of normal operating-system file sharing.

Explanation

Correct Answer

C:

Electrostatic discharge can damage small semiconductor features even without an immediately observable spark. This is the governing technical explanation for Preventing static damage while replacing a riser card. Correct configuration: Follow approved service isolation, antistatic wrist-strap, ESD mat and component-handling procedures before replacing the card. Observable outcome: Postreplacement hardware diagnostics show the adapter enumerates correctly with no new intermittent errors after a controlled startup.

Incorrect Answers

A:

Rack airflow orientation, containment and cable obstruction control where cold air reaches equipment rather than just room cooling setpoints. That principle describes Correcting rack cooling when front-to-back airflow is blocked, not the mechanism that governs Preventing static damage while replacing a riser card. The relevant principle is: Electrostatic discharge can damage small semiconductor features even without an immediately observable spark.

B:

RAID parity provides physical availability, whereas backup restores data after logical damage or destructive events. That principle describes Distinguishing RAID 6 redundancy from two independent backups, not the mechanism that governs Preventing static damage while replacing a riser card. The relevant principle is: Electrostatic discharge can damage small semiconductor features even without an immediately observable spark.

D:

BMC virtual media can emulate removable boot devices independently of normal operating-system file sharing. That principle describes Rebinding virtual media for an authorized remote OS installation, not the mechanism that governs Preventing static damage while replacing a riser card. The relevant principle is: Electrostatic discharge can damage small semiconductor features even without an immediately observable spark.

Question 54

The server team omits a necessary safeguard. A technician opens a powered-down rack server in a carpeted work area, removes a PCIe riser without a grounding procedure and places it on conductive packaging. Which resulting operational or security exposure is the most direct?

  1. A mismatched optic may show intermittent link flaps or excessive bit errors that appear to be disk latency.
  2. A depleted battery can cause certificate failures, boot confusion and repeated downtime after power maintenance.
  3. Capacity shortfall can block production ingest despite purchase orders showing the nominal required terabytes.
  4. Improper handling may create latent failures that emerge after the production change window closes.

Explanation

Correct Answer

D:

Improper handling may create latent failures that emerge after the production change window closes. This is the central risk in Preventing static damage while replacing a riser card. Appropriate safeguard: Follow approved service isolation, antistatic wrist-strap, ESD mat and component-handling procedures before replacing the card. Evidence the safeguard works: Postreplacement hardware diagnostics show the adapter enumerates correctly with no new intermittent errors after a controlled startup.

Incorrect Answers

A:

A mismatched optic may show intermittent link flaps or excessive bit errors that appear to be disk latency. This exposure applies to Matching SFP optics and fiber type to the intended link, not the direct consequence of Preventing static damage while replacing a riser card. The actual case-specific risk is: Improper handling may create latent failures that emerge after the production change window closes.

B:

A depleted battery can cause certificate failures, boot confusion and repeated downtime after power maintenance. This exposure applies to Replacing a CMOS battery while preserving critical firmware settings, not the direct consequence of Preventing static damage while replacing a riser card. The actual case-specific risk is: Improper handling may create latent failures that emerge after the production change window closes.

C:

Capacity shortfall can block production ingest despite purchase orders showing the nominal required terabytes. This exposure applies to Calculating usable RAID storage with parity and spare overhead, not the direct consequence of Preventing static damage while replacing a riser card. The actual case-specific risk is: Improper handling may create latent failures that emerge after the production change window closes.

Question 55

The server fault remains unresolved: A technician opens a powered-down rack server in a carpeted work area, removes a PCIe riser without a grounding procedure and places it on conductive packaging. Which evidence should be examined first to diagnose this particular issue?

  1. Inspect ESD controls, service procedure, packaging, power isolation and post-change hardware event logs.
  2. Inspect rack elevation, chassis weights, rack rating, anti-tip hardware and the facilities floor-loading approval.
  3. Inspect firmware clock drift, battery voltage, boot order changes, event history and postreplacement power-cycle tests.
  4. Inspect controller cache mode, battery health, event logs, drive status and application consistency checks.

Explanation

Correct Answer

A:

Inspect ESD controls, service procedure, packaging, power isolation and post-change hardware event logs. These checks target the described failure in Preventing static damage while replacing a riser card. Appropriate response: Follow approved service isolation, antistatic wrist-strap, ESD mat and component-handling procedures before replacing the card. Success criteria: Postreplacement hardware diagnostics show the adapter enumerates correctly with no new intermittent errors after a controlled startup.

Incorrect Answers

B:

Inspect rack elevation, chassis weights, rack rating, anti-tip hardware and the facilities floor-loading approval. Those checks investigate Rack floor-loading calculation before mounting dense storage arrays instead of the Preventing static damage while replacing a riser card failure. The focused investigation should be: Inspect ESD controls, service procedure, packaging, power isolation and post-change hardware event logs.

C:

Inspect firmware clock drift, battery voltage, boot order changes, event history and postreplacement power-cycle tests. Those checks investigate Replacing a CMOS battery while preserving critical firmware settings instead of the Preventing static damage while replacing a riser card failure. The focused investigation should be: Inspect ESD controls, service procedure, packaging, power isolation and post-change hardware event logs.

D:

Inspect controller cache mode, battery health, event logs, drive status and application consistency checks. Those checks investigate Distinguishing an SSD caching fault from lost underlying data instead of the Preventing static damage while replacing a riser card failure. The focused investigation should be: Inspect ESD controls, service procedure, packaging, power isolation and post-change hardware event logs.

Question 56

A CompTIA Server+ SK0-005 administrator reviews this production scenario: A financial database needs consistently low write latency with local disk fault tolerance, while a designer proposes RAID 0 across four spinning drives solely for speed. Which configuration or design change most directly solves the requirement?

  1. Keep RAID 6 for appropriate disk fault tolerance but add independent versioned and tested backups for corruption, deletion and site disasters.
  2. Choose RAID 10 with an appropriate tested controller and disk count after confirming write workload, required capacity and tolerated failures.
  3. Move the heavy chassis to approved lower rack units after facilities verifies rated floor capacity and the vendor's rail and lifting requirements.
  4. Follow the approved firmware compatibility matrix and staged maintenance process, updating components in the required order with rollback evidence.

Explanation

Correct Answer

B:

Choose RAID 10 with an appropriate tested controller and disk count after confirming write workload, required capacity and tolerated failures. Technical basis: RAID 10 stripes across mirrored disk groups, reducing parity write overhead while retaining defined drive redundancy. Acceptance evidence: Random-write benchmarks and a controlled single-drive loss remain within approved performance and service-availability targets. Deployment boundary: Confirm the server vendor hardware compatibility list, current operating system or hypervisor support, approved permissions, maintenance and backup processes before applying this educational example to production.

Incorrect Answers

A:

Keep RAID 6 for appropriate disk fault tolerance but add independent versioned and tested backups for corruption, deletion and site disasters. This is a sensible intervention in the separate Distinguishing RAID 6 redundancy from two independent backups scenario. It does not resolve the present Selecting RAID 10 for low-latency transactional writes requirement. For the current problem, use: Choose RAID 10 with an appropriate tested controller and disk count after confirming write workload, required capacity and tolerated failures.

C:

Move the heavy chassis to approved lower rack units after facilities verifies rated floor capacity and the vendor's rail and lifting requirements. This is a sensible intervention in the separate Rack floor-loading calculation before mounting dense storage arrays scenario. It does not resolve the present Selecting RAID 10 for low-latency transactional writes requirement. For the current problem, use: Choose RAID 10 with an appropriate tested controller and disk count after confirming write workload, required capacity and tolerated failures.

D:

Follow the approved firmware compatibility matrix and staged maintenance process, updating components in the required order with rollback evidence. This is a sensible intervention in the separate Installing server firmware without skipping compatibility sequencing scenario. It does not resolve the present Selecting RAID 10 for low-latency transactional writes requirement. For the current problem, use: Choose RAID 10 with an appropriate tested controller and disk count after confirming write workload, required capacity and tolerated failures.

Question 57

During a CompTIA Server+ incident recovery verification, the team observes: A financial database needs consistently low write latency with local disk fault tolerance, while a designer proposes RAID 0 across four spinning drives solely for speed. Which result is the most convincing evidence of the required outcome?

  1. A controlled loss of one boot device leaves the host serviceable or recoverable within the documented maintenance objective.
  2. Random-write benchmarks and a controlled single-drive loss remain within approved performance and service-availability targets.
  3. A controlled loss of either approved PDU leaves the server running without overload or unsafe backfeeding through the surviving feed.
  4. The replacement fan registers normal RPM and inlet temperatures remain within limits after a sustained workload test.

Explanation

Correct Answer

B:

Random-write benchmarks and a controlled single-drive loss remain within approved performance and service-availability targets. This directly verifies Selecting RAID 10 for low-latency transactional writes. Required action: Choose RAID 10 with an appropriate tested controller and disk count after confirming write workload, required capacity and tolerated failures. Why it is a suitable test: RAID 10 stripes across mirrored disk groups, reducing parity write overhead while retaining defined drive redundancy.

Incorrect Answers

A:

A controlled loss of one boot device leaves the host serviceable or recoverable within the documented maintenance objective. This verifies the separate Choosing mirrored boot storage instead of one removable OS drive situation rather than Selecting RAID 10 for low-latency transactional writes. The decisive outcome here is: Random-write benchmarks and a controlled single-drive loss remain within approved performance and service-availability targets.

C:

A controlled loss of either approved PDU leaves the server running without overload or unsafe backfeeding through the surviving feed. This verifies the separate Separating two server power supplies across failure domains situation rather than Selecting RAID 10 for low-latency transactional writes. The decisive outcome here is: Random-write benchmarks and a controlled single-drive loss remain within approved performance and service-availability targets.

D:

The replacement fan registers normal RPM and inlet temperatures remain within limits after a sustained workload test. This verifies the separate Choosing a supported hot-swap fan repair under load situation rather than Selecting RAID 10 for low-latency transactional writes. The decisive outcome here is: Random-write benchmarks and a controlled single-drive loss remain within approved performance and service-availability targets.

Question 58

A server administrator explains the technical behavior behind this situation: A financial database needs consistently low write latency with local disk fault tolerance, while a designer proposes RAID 0 across four spinning drives solely for speed. Which technical principle most directly explains the correct approach?

  1. RAID 10 stripes across mirrored disk groups, reducing parity write overhead while retaining defined drive redundancy.
  2. RAID 5 tolerates one failed member, so accidental removal of another live disk can exceed redundancy.
  3. Hot-swap serviceability is component-specific and cooling redundancy decreases temporarily during repair.
  4. Cable routing is part of serviceability and resiliency because moving chassis can mechanically compromise redundant feeds.

Explanation

Correct Answer

A:

RAID 10 stripes across mirrored disk groups, reducing parity write overhead while retaining defined drive redundancy. This is the governing technical explanation for Selecting RAID 10 for low-latency transactional writes. Correct configuration: Choose RAID 10 with an appropriate tested controller and disk count after confirming write workload, required capacity and tolerated failures. Observable outcome: Random-write benchmarks and a controlled single-drive loss remain within approved performance and service-availability targets.

Incorrect Answers

B:

RAID 5 tolerates one failed member, so accidental removal of another live disk can exceed redundancy. That principle describes Repairing a degraded RAID 5 without pulling the wrong drive, not the mechanism that governs Selecting RAID 10 for low-latency transactional writes. The relevant principle is: RAID 10 stripes across mirrored disk groups, reducing parity write overhead while retaining defined drive redundancy.

C:

Hot-swap serviceability is component-specific and cooling redundancy decreases temporarily during repair. That principle describes Choosing a supported hot-swap fan repair under load, not the mechanism that governs Selecting RAID 10 for low-latency transactional writes. The relevant principle is: RAID 10 stripes across mirrored disk groups, reducing parity write overhead while retaining defined drive redundancy.

D:

Cable routing is part of serviceability and resiliency because moving chassis can mechanically compromise redundant feeds. That principle describes Separating production and management power cable routes, not the mechanism that governs Selecting RAID 10 for low-latency transactional writes. The relevant principle is: RAID 10 stripes across mirrored disk groups, reducing parity write overhead while retaining defined drive redundancy.

Question 59

The server team omits a necessary safeguard. A financial database needs consistently low write latency with local disk fault tolerance, while a designer proposes RAID 0 across four spinning drives solely for speed. Which resulting operational or security exposure is the most direct?

  1. RAID 0 makes every disk failure a full array outage and offers no recovery safety net.
  2. Ransomware or accidental deletion can remove the only usable data even when every parity disk is healthy.
  3. Ad hoc peripheral swapping can disconnect the wrong host and delay safe recovery of an outage.
  4. A depleted battery can cause certificate failures, boot confusion and repeated downtime after power maintenance.

Explanation

Correct Answer

A:

RAID 0 makes every disk failure a full array outage and offers no recovery safety net. This is the central risk in Selecting RAID 10 for low-latency transactional writes. Appropriate safeguard: Choose RAID 10 with an appropriate tested controller and disk count after confirming write workload, required capacity and tolerated failures. Evidence the safeguard works: Random-write benchmarks and a controlled single-drive loss remain within approved performance and service-availability targets.

Incorrect Answers

B:

Ransomware or accidental deletion can remove the only usable data even when every parity disk is healthy. This exposure applies to Distinguishing RAID 6 redundancy from two independent backups, not the direct consequence of Selecting RAID 10 for low-latency transactional writes. The actual case-specific risk is: RAID 0 makes every disk failure a full array outage and offers no recovery safety net.

C:

Ad hoc peripheral swapping can disconnect the wrong host and delay safe recovery of an outage. This exposure applies to Using a dedicated KVM path for shared emergency administration, not the direct consequence of Selecting RAID 10 for low-latency transactional writes. The actual case-specific risk is: RAID 0 makes every disk failure a full array outage and offers no recovery safety net.

D:

A depleted battery can cause certificate failures, boot confusion and repeated downtime after power maintenance. This exposure applies to Replacing a CMOS battery while preserving critical firmware settings, not the direct consequence of Selecting RAID 10 for low-latency transactional writes. The actual case-specific risk is: RAID 0 makes every disk failure a full array outage and offers no recovery safety net.

Question 60

The server fault remains unresolved: A financial database needs consistently low write latency with local disk fault tolerance, while a designer proposes RAID 0 across four spinning drives solely for speed. Which evidence should be examined first to diagnose this particular issue?

  1. Inspect DWPD/TBW rating, SMART wear indicators, write rate, controller amplification and replacement forecasts.
  2. Inspect PSU input readings, PDU outlets, breaker mappings, UPS sources, circuit capacities and failover test logs.
  3. Inspect console-server ACLs, SSH or TLS access, port mapping, audit trail and recovery tests.
  4. Inspect controller policy, disk grouping, write latency, usable capacity and degraded-array behavior.

Explanation

Correct Answer

D:

Inspect controller policy, disk grouping, write latency, usable capacity and degraded-array behavior. These checks target the described failure in Selecting RAID 10 for low-latency transactional writes. Appropriate response: Choose RAID 10 with an appropriate tested controller and disk count after confirming write workload, required capacity and tolerated failures. Success criteria: Random-write benchmarks and a controlled single-drive loss remain within approved performance and service-availability targets.

Incorrect Answers

A:

Inspect DWPD/TBW rating, SMART wear indicators, write rate, controller amplification and replacement forecasts. Those checks investigate Managing write-intensive SSD wear rather than capacity only instead of the Selecting RAID 10 for low-latency transactional writes failure. The focused investigation should be: Inspect controller policy, disk grouping, write latency, usable capacity and degraded-array behavior.

B:

Inspect PSU input readings, PDU outlets, breaker mappings, UPS sources, circuit capacities and failover test logs. Those checks investigate Separating two server power supplies across failure domains instead of the Selecting RAID 10 for low-latency transactional writes failure. The focused investigation should be: Inspect controller policy, disk grouping, write latency, usable capacity and degraded-array behavior.

C:

Inspect console-server ACLs, SSH or TLS access, port mapping, audit trail and recovery tests. Those checks investigate Isolating serial console paths for legacy network appliances instead of the Selecting RAID 10 for low-latency transactional writes failure. The focused investigation should be: Inspect controller policy, disk grouping, write latency, usable capacity and degraded-array behavior.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Purchase Individually

  • Premium File

    617 Questions & Answers
    Last Update: Nov 9, 2026

    $76.99
    $69.99
  • Training Course

    139 Lectures

    $43.99
    $39.99
  • Study Guide

    533 Pages

    $43.99
    $39.99

SPECIAL OFFER: GET 10% OFF
This is ONE TIME OFFER

You save
10%

Enter Your Email Address to Receive Your 10% Off Discount Code

SPECIAL OFFER: GET 10% OFF

You save
10%

Use Discount Code:

A confirmation link was sent to your e-mail.

Please check your mailbox for a message from support@examlabs.com and follow the directions.

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your email address below to get started with our interactive software demo of your free trial.

  • Realistic exam simulation and exam editor with preview functions
  • Whole exam in a single file with several different question types
  • Customizable exam-taking mode & detailed score reports